Hybrid OR room 14: Difference between revisions
From Bay Area Structural Heart Wiki
setup |
|||
(7 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
'''Long table top for all procedures. ''' | |||
'''Verify necessary ECMO equipment in OR sterile core Pyxis''' | |||
'''Shield for Anesthesia''' | |||
===Zeego=== | |||
*Move c-arm to patient transport position before bringing any large equipment into the room. | |||
**Working position: table rotated 15*. | |||
*If procedure requires TEE, have echo move into position before bringing c-arm in. | |||
*Verify monitor elbow in correct position before draping. | |||
=== | ===Storz Display=== | ||
* | *VIntegration 2- Echo | ||
* | *VIntegration 1- Anesthesia Vitals | ||
* | *Camera for monitor person | ||
==ITEMS TO BRING:== | |||
*TO GO Cart | |||
*Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1 | |||
*Cath Packs | |||
*Staff and MD Lead | |||
*Long scrub table from end of hall | |||
*Contrast | |||
===MITRACLIP=== | |||
* | *Structural Cart | ||
* | *Plug Cart | ||
*Baylis | |||
*Baylis Cable | |||
*Mitraclip guide and multiple of each size clip. | |||
*Stabilizer | |||
*Plexiglass and stabilizer lift | |||
*IV Pole with at least (2) 1000 mL pressure bags. | |||
**may need a second pole and set of bags if it is known in advance a second clip is needed | |||
*Gel Pads | |||
*Contrast attached to manifold if coronary angiogram to be performed | |||
=== | ===TAVR=== | ||
* | *ACIST Setup | ||
* | *TAVR Cart | ||
* | *Structural Cart | ||
* | *Plug Cart- can be parked outside the door | ||
*Delivery System and other vendor specific equipment from store room. | |||
*''Sentinel: Radial board and Verapamil'' | |||
* | |||
* | |||
===TMVR=== | |||
*Baylis | |||
*Baylis Cable | |||
*TAVR Cart | |||
*Structural Cart | |||
*Plug Cart | |||
*Delivery system and other vendor specific equipment from store room | |||
[[Category:Setups]] | |||
Latest revision as of 21:34, 7 January 2025
Long table top for all procedures.
Verify necessary ECMO equipment in OR sterile core Pyxis
Shield for Anesthesia
Zeego
- Move c-arm to patient transport position before bringing any large equipment into the room.
- Working position: table rotated 15*.
- If procedure requires TEE, have echo move into position before bringing c-arm in.
- Verify monitor elbow in correct position before draping.
Storz Display
- VIntegration 2- Echo
- VIntegration 1- Anesthesia Vitals
- Camera for monitor person
ITEMS TO BRING:
- TO GO Cart
- Hep saline, lidocaine, bupivicaine, protamine, iStat supplies from cath lab 1
- Cath Packs
- Staff and MD Lead
- Long scrub table from end of hall
- Contrast
MITRACLIP
- Structural Cart
- Plug Cart
- Baylis
- Baylis Cable
- Mitraclip guide and multiple of each size clip.
- Stabilizer
- Plexiglass and stabilizer lift
- IV Pole with at least (2) 1000 mL pressure bags.
- may need a second pole and set of bags if it is known in advance a second clip is needed
- Gel Pads
- Contrast attached to manifold if coronary angiogram to be performed
TAVR
- ACIST Setup
- TAVR Cart
- Structural Cart
- Plug Cart- can be parked outside the door
- Delivery System and other vendor specific equipment from store room.
- Sentinel: Radial board and Verapamil
TMVR
- Baylis
- Baylis Cable
- TAVR Cart
- Structural Cart
- Plug Cart
- Delivery system and other vendor specific equipment from store room