Hongo Farapulse: Difference between revisions

From Bay Area Structural Heart Wiki
Rosenbzj (talk | contribs)
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 43: Line 43:
   
   
2x 8f Pinnacle  
2x 8f Pinnacle  


1x 10.5f FastCath
1x 10.5f FastCath


3x pressure tubing + 1 stopcock
3x pressure tubing + 1 stopcock


ACT line
ACT line


Ice Sleeve
Ice Sleeve


Ioban
Ioban


Ultrasound Sleeve
Ultrasound Sleeve
Line 65: Line 59:


BW CS
BW CS


10.5f SoundStar
10.5f SoundStar


LAMP
LAMP


Baylis 71cm C0
Baylis 71cm C0


Rosen 1.5mmJ 180cm
Rosen 1.5mmJ 180cm


Farawave (31mm default), Farastar, Faradrive


Farawave (31mm default), Farastar, Faradrive
[[Category:Ablations]]

Latest revision as of 21:10, 7 January 2025

work in progress

General:

-Consent - Electrophysiology Study with Catheter Ablation

-Patient intubated/paralyzed (long acting) throughout procedure

-No foley, no enso

-No isuprel

-Antibiotics

-Fluoro

-Goal ACT>300

-MacLab leads, Anesthesia leads, Carto 12 lead

-1 Ground, carto patches, regular defib pad


Pyxis/Bags to make/Lines - need to fill out further

2 hanging bags of 5000u in 500cc


1L 10000u in 1000cc for table


1L LR Anesthesia 500cc NS ACT line


Drop List

EP Pack

1 perclose, 2 vascade

Rampart/Radpad

2x 8f Pinnacle

1x 10.5f FastCath

3x pressure tubing + 1 stopcock

ACT line

Ice Sleeve

Ioban

Ultrasound Sleeve

Penta Cable, Baylis Cable, CS Cable

BW CS

10.5f SoundStar

LAMP

Baylis 71cm C0

Rosen 1.5mmJ 180cm

Farawave (31mm default), Farastar, Faradrive