Transjugular Liver Biopsy: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
 
(One intermediate revision by the same user not shown)
Line 7: Line 7:
*Tube left side, tilt table and tube to visualize liver.   
*Tube left side, tilt table and tube to visualize liver.   
*Will measure pressures.  
*Will measure pressures.  
*PPM indicates pressure measurements


==Supplies==
==Supplies==
Line 18: Line 19:
*Pressure Transducer  
*Pressure Transducer  
*Torque device  
*Torque device  
*9Fr sheath  
*9x38 Cook sheath (near tlab set)
*TLAB kit (comes with MPB catheter, 7Fr introducer and Biopsy needle)  
*TLAB kit (comes with MPB catheter, 7Fr introducer and Biopsy needle)  
*12cc syringe, for extra contrast  
*12cc syringe, for extra contrast  

Latest revision as of 20:59, 20 November 2024

TRANSJUGULAR LIVER BX W/WO PRESSURES

  • 100% Contrast (hand injection) unless the Physician states otherwise.
  • Heparinized Saline 1000 ml
  • T table setup, work from head side.
  • Tube left side, tilt table and tube to visualize liver.
  • Will measure pressures.
  • PPM indicates pressure measurements

Supplies

Open

  • Angio pack
  • Fluoro drape
  • Probe cover
  • Micropuncture kit
  • Amplatz SS 180cm
  • Glide wire angled regular 180cm
  • Pressure Transducer
  • Torque device
  • 9x38 Cook sheath (near tlab set)
  • TLAB kit (comes with MPB catheter, 7Fr introducer and Biopsy needle)
  • 12cc syringe, for extra contrast
  • Telfa (to place specimen on)
  • Sureseal

Standby

  • C2 catheter

With pressures

  • 8mm Occlusion balloon
  • One way stopcock


Bronzo

  • No torque device

Dare

Raj

  • Flowswitch


Brittany

Will use cope wire in the kit


Evan

Micropuncture kit (Cook)

Samir

  • 10Fr dilator

Lynne

  • Flowswitch