Aveir: Difference between revisions

From Bay Area Structural Heart Wiki
(Created page with "RN: -2x 1L bags NS with 2000u heparin per liter bag. One bag on gravity (these 2 lines will be labeled A/B), one on pressure (these 2 lines will be labeled C/D). 4x non pump tubings (2 per bag) labeled as listed above, spiked and primed. Optionally, if you want to clear the air from the gravity (A/B) lines faster, you can put it on pressure to flush, then immediately come off pressure after they're flushed, as gravity is required per protocol. -double label each line -...")
 
No edit summary
 
(11 intermediate revisions by 2 users not shown)
Line 1: Line 1:
RN:
'''<big>RN:</big>'''
-2x 1L bags NS with 2000u heparin per liter bag. One bag on gravity (these 2 lines will be labeled A/B), one on pressure (these 2 lines will be labeled C/D). 4x non pump tubings (2 per bag) labeled as listed above, spiked and primed. Optionally, if you want to clear the air from the gravity (A/B) lines faster, you can put it on pressure to flush, then immediately come off pressure after they're flushed, as gravity is required per protocol.  
 
-For single chamber Aveir, 2x 1L bags NS with 2000u heparin per liter bag, double spiked.  
 
-For dual chamber Aveir, 4x 1L bags NS with 2000u heparin per liter bag, single spiked. 
 
-Whether 2 or 4 bags, the lines labeled A/B will be on gravity, and the lines labeled C/D will be on pressure. 4x non pump tubings (2 per bag) labeled as listed above, spiked and primed. Optionally, if you want to clear the air from the gravity (A/B) lines faster, you can put it on pressure to flush, then come off pressure after they're flushed, as they need to be on gravity during the case per protocol.  


-double label each line - one on roller clamp and one on the end where you attach to the extension.  
-double label each line - one on roller clamp and one on the end where you attach to the extension.  
Line 6: Line 11:
-MD will verbalize when to flush and when to set to 1 drop per second (via roller clamp.)
-MD will verbalize when to flush and when to set to 1 drop per second (via roller clamp.)


-1L heparinized saline on the scrub table
-1L heparinized saline (10,000u heparin) on the scrub table
 
-50cc omnipaque or visipaque if indicated (can be cut to ~50/50)


-50cc omnipaque or visi if indicated (can be cut to ~50/50)
-lidocaine/bupivicaine


-lido/bupi
'''<big>Tech:</big>'''
 
-All Romick Aveirs: drop a 6f pinnacle & 6f angled pigtail.
 
-All RA Hongo Aveirs get a 6f angled pigtail + a 3way stopcock, but as of 6/26/24 he wants to put the pig into the Aveir introducer so that we only start with a single 8f access. Some RV Hongo Aveirs will use an angled pig as well, check before dropping.


Tech:
-4x pressure tubing (labeled A, B, C, D)
-4x pressure tubing (labeled A, B, C, D)


-50-60cc syringe
-50-60cc syringe x2
 
-8fr pinnacle (or 8f dilator)
 
'''(Romick)''' 7cm floppy tip 180cm .035" amplatz super stiff ||||||||||
 
'''(Hongo)''' 180cm 0.35" amplatz (purple cheater)
 
-dilator 20f coons (altternatives: Endovascular Dilator Set (20 or 22), cook short dilators. Aveir sheath is 27f.)
 
'''(Romick)''' 0.0 PDS + needle driver.
 
'''(Hongo)''' 2x preclose
 
-radpad
 
-rampart cover (romick only)
 
-ioban
 
-access cover x2 (tee/linear)
 
-light handle cover
 
-possible additional 8f acunav, ice sleeve, 8f pinnacle (check w/MD)
 
 
 


-micropuncture + 8fr pinnacle (or 8f dilator)


-7cm floppytip 180cm amplatz xtra stiff


-dilators 12/18/24 short cooks


-0.0 PDS + needle driver
created 03/29/23 zr

Latest revision as of 00:15, 20 November 2024

RN:

-For single chamber Aveir, 2x 1L bags NS with 2000u heparin per liter bag, double spiked.

-For dual chamber Aveir, 4x 1L bags NS with 2000u heparin per liter bag, single spiked.

-Whether 2 or 4 bags, the lines labeled A/B will be on gravity, and the lines labeled C/D will be on pressure. 4x non pump tubings (2 per bag) labeled as listed above, spiked and primed. Optionally, if you want to clear the air from the gravity (A/B) lines faster, you can put it on pressure to flush, then come off pressure after they're flushed, as they need to be on gravity during the case per protocol.

-double label each line - one on roller clamp and one on the end where you attach to the extension.

-MD will verbalize when to flush and when to set to 1 drop per second (via roller clamp.)

-1L heparinized saline (10,000u heparin) on the scrub table

-50cc omnipaque or visipaque if indicated (can be cut to ~50/50)

-lidocaine/bupivicaine

Tech:

-All Romick Aveirs: drop a 6f pinnacle & 6f angled pigtail.

-All RA Hongo Aveirs get a 6f angled pigtail + a 3way stopcock, but as of 6/26/24 he wants to put the pig into the Aveir introducer so that we only start with a single 8f access. Some RV Hongo Aveirs will use an angled pig as well, check before dropping.

-4x pressure tubing (labeled A, B, C, D)

-50-60cc syringe x2

-8fr pinnacle (or 8f dilator)

(Romick) 7cm floppy tip 180cm .035" amplatz super stiff ||||||||||

(Hongo) 180cm 0.35" amplatz (purple cheater)

-dilator 20f coons (altternatives: Endovascular Dilator Set (20 or 22), cook short dilators. Aveir sheath is 27f.)

(Romick) 0.0 PDS + needle driver.

(Hongo) 2x preclose

-radpad

-rampart cover (romick only)

-ioban

-access cover x2 (tee/linear)

-light handle cover

-possible additional 8f acunav, ice sleeve, 8f pinnacle (check w/MD)




created 03/29/23 zr