PFO: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
 
(18 intermediate revisions by 4 users not shown)
Line 1: Line 1:
<br />
<br />


==Hui - Draft==
== Daniels - PFO ==
Sheaths:
*Micropuncture
*8F Pinnacle
*9F 25cm Pinnacle ( When using ICE )
 
===Wires:===
 
*Rosen for crossing and deployment
*angled glide on standby


===Sheaths:===
===Catheters:===


====Open====
*5F MP1


*6fr x 10 Pinnacle
===Misc. Supplies:===
*(2) 8fr x 10 Pinnacle


<br />
*Ultrasound probe cover
===Wires:===
*(1) Perclose
*50 cc syringe for sizing balloon
*3-way stop cock for bubble study
*Sizing balloon of MD choice
*TorqView or Trevisio delivery
*lido with epi and glue at end of case


====Open====
===ICE:===


*Amplatz extra stiff 260J
*8Fr AccuNav Catheter (PFO cart)
*Cordis straight 150
*Swift link cover
*AccuNav Intracardiac Imaging machine
*Echo tech


<br />
===Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS===
===Catheters:===


====Open====
*TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
*Device = PFO OCCLUDERS (Range : 18, 25, 35 mm) ; Cardioforms
*Sizing balloon (18, 24)


*6Fr MPB2 100 cm diagnostic
==Spies - PFO==
8F AccuNav when using ICE


<br />
*No need for manifold set up with Spies unless he wants to measure for pulmonary hypertension
===Misc. Supplies:===
*If no anesthesia than no art line needed
*Echo tech to run ICE


====Open====
===Sheaths:===


*Probe cover
*Micropuncture
*Micropuncture
*8F Pinnacle
*9F 25cm Pinnacle ( When using ICE )


*2 - port manifold with stopcock and 20cc syringe
===Wires:===
*Swift Link (AccuNav) Probe Cover
 
*Standard J (used to cross)
*Rosen (on standby)
*Amplatz Extra Stiff (used to deploy)
 
===Catheters:===


*60 ml syringe
*5F MP1
*20 ml syringe


====Standby====
===Misc. Supplies:===


*Perclose
*Ultrasound probe cover
*(2) Perclose  
*50 cc syringe for sizing balloon
*3-way stop cock for bubble study
*Sizing balloon of MD choice
*TorqView or Trevisio delivery
*lido with epi and glue at end of case


<br />
===ICE:===
===ICE===


*8Fr AccuNav Catheter (PFO cart)
*8Fr AccuNav Catheter (PFO cart)
*Swift link cover
*AccuNav Intracardiac Imaging machine
*AccuNav Intracardiac Imaging machine
*Echo tech


<br />
===Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS===
===Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS===


*TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
*TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
*Device = PFO OCCLUDERS (Range : 18, 25, 35 mm)
*Device = PFO OCCLUDERS (Range : 18, 25, 35 mm) ; Cardioforms
*Sizing balloon (18, 24)
*Sizing balloon (18, 24)


<br />
== Agrawal ==
===Pericardiocentesis (Standby)===


*Pericardiocentesis tray
=== Sheaths : ===


<br />
* Micropuncture
* 8F Pinnacle


===Device Thrombosis/Retrieval Supplies===
=== Wires: ===


*16 or 18 Fr Dry Seal Sheath
* Standard J Wire
*6 or 7 Fr Ensnare Kit or Gooseneck Snare
* Amplatz Super Stiff 1cm Tip


<BR />
=== Catheters: ===
<hr />
Approved: MM/YY
==Walsh - Draft==


===Sheaths:===
* 6F MPB2 100cm Diagnostic catheter


====Open====
=== Other Supplies: ===
* Perclose (Second perclose when using ICE)
* 2 port manifold for LA pressure


*9fr x 10 Pinnacle
=== ICE Supplies: ===
*8fr x 10 Pinnacle


<br />
* 6F Pinnacle to dilate
* 9F 23 cm Pinnacle for ICE (Structural cart)
* Swift Link cover (Structural cart or EP)
* Echo Tech


===Wires:===
=== Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS ===
*TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
*Device = PFO OCCLUDERS (Range : 18, 25, 35 mm)
*Sizing balloon (18, 24)
==Hui - Draft==


====Open====
===Sheaths: Open===


*Cordis 260J
*9F 23cm Pinnacle for ICE
*Micropuncture
*11F Pinnacle
===Wires: Open===


====Standby====
*Cope
*Amplatz extra stiff 260J
*Cordis straight 150
*Standard J Wire
===Catheters: Open===


*Amplatz Super Stiff 0.035 x 260 cm
*6Fr MPB2 100 cm diagnostic
*Amplatzer Guide 0.035 x 260 cm ???
*


<br />
===Misc. Supplies: Open===
===Catheters:===


====Open====
*Probe cover
*2 - port manifold with stopcock and 20cc syringe
*Swift Link (AccuNav) Probe Cover
*20 ml syringe


*5Fr MPA 100 cm diagnostic<br />
====Standby====
 
===Misc. Supplies:===
 
====Open====


*Probe cover
*Micropuncture
*Perclose
*Perclose


*3 - port manifold
*25g  1 ½ “ Daniels Femoral Needle
*Swift Link (AccuNav) Probe Cover
*3 – way stopcock for intravenous bubble study performed by MD
*60 ml syringe
*20 ml syringe
<br />
===ICE===
===ICE===


*8Fr AccuNav Catheter (PFO cart)
*8Fr AccuNav Catheter (PFO cart)
*AccuNav Intracardiac Imaging machine
*AccuNav Intracardiac Imaging machine
*SwiftLink cover
*9frx23cm Pinnacle (Spies only)


<br />
===Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS===
===Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS===


*TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
*TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
*Device = PFO OCCLUDERS (Range : 18, 25, 35 mm)
*Device = PFO OCCLUDERS (Range : 18, 25, 35 mm)
*Sizing balloon (18, 24)
===Pericardiocentesis (Standby)===


<br />
*Pericardiocentesis tray
===Pericardiocentesis (Standby)===
 
===Device Thrombosis/Retrieval Supplies===
 
*16 or 18 Fr Dry Seal Sheath
*6 or 7 Fr Ensnare Kit or Gooseneck Snare
 
 
 
 
==PERICARDIOCENTESIS==


{{Pericardiocentesis}}
{{Pericardiocentesis}}


<br />
===Device Thrombosis/Retrieval Supplies===
===Device Thrombosis/Retrieval Supplies===



Latest revision as of 18:49, 19 November 2024


Daniels - PFO

Sheaths:

  • Micropuncture
  • 8F Pinnacle
  • 9F 25cm Pinnacle ( When using ICE )

Wires:

  • Rosen for crossing and deployment
  • angled glide on standby

Catheters:

  • 5F MP1

Misc. Supplies:

  • Ultrasound probe cover
  • (1) Perclose
  • 50 cc syringe for sizing balloon
  • 3-way stop cock for bubble study
  • Sizing balloon of MD choice
  • TorqView or Trevisio delivery
  • lido with epi and glue at end of case

ICE:

  • 8Fr AccuNav Catheter (PFO cart)
  • Swift link cover
  • AccuNav Intracardiac Imaging machine
  • Echo tech

Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS

  • TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
  • Device = PFO OCCLUDERS (Range : 18, 25, 35 mm) ; Cardioforms
  • Sizing balloon (18, 24)

Spies - PFO

8F AccuNav when using ICE

  • No need for manifold set up with Spies unless he wants to measure for pulmonary hypertension
  • If no anesthesia than no art line needed
  • Echo tech to run ICE

Sheaths:

  • Micropuncture
  • 8F Pinnacle
  • 9F 25cm Pinnacle ( When using ICE )

Wires:

  • Standard J (used to cross)
  • Rosen (on standby)
  • Amplatz Extra Stiff (used to deploy)

Catheters:

  • 5F MP1

Misc. Supplies:

  • Ultrasound probe cover
  • (2) Perclose
  • 50 cc syringe for sizing balloon
  • 3-way stop cock for bubble study
  • Sizing balloon of MD choice
  • TorqView or Trevisio delivery
  • lido with epi and glue at end of case

ICE:

  • 8Fr AccuNav Catheter (PFO cart)
  • Swift link cover
  • AccuNav Intracardiac Imaging machine
  • Echo tech

Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS

  • TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
  • Device = PFO OCCLUDERS (Range : 18, 25, 35 mm) ; Cardioforms
  • Sizing balloon (18, 24)

Agrawal

Sheaths :

  • Micropuncture
  • 8F Pinnacle

Wires:

  • Standard J Wire
  • Amplatz Super Stiff 1cm Tip

Catheters:

  • 6F MPB2 100cm Diagnostic catheter

Other Supplies:

  • Perclose (Second perclose when using ICE)
  • 2 port manifold for LA pressure

ICE Supplies:

  • 6F Pinnacle to dilate
  • 9F 23 cm Pinnacle for ICE (Structural cart)
  • Swift Link cover (Structural cart or EP)
  • Echo Tech

Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS

  • TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
  • Device = PFO OCCLUDERS (Range : 18, 25, 35 mm)
  • Sizing balloon (18, 24)

Hui - Draft

Sheaths: Open

  • 9F 23cm Pinnacle for ICE
  • Micropuncture
  • 11F Pinnacle

Wires: Open

  • Cope
  • Amplatz extra stiff 260J
  • Cordis straight 150
  • Standard J Wire

Catheters: Open

  • 6Fr MPB2 100 cm diagnostic

Misc. Supplies: Open

  • Probe cover
  • 2 - port manifold with stopcock and 20cc syringe
  • Swift Link (AccuNav) Probe Cover
  • 20 ml syringe

Standby

  • Perclose

ICE

  • 8Fr AccuNav Catheter (PFO cart)
  • AccuNav Intracardiac Imaging machine

Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS

  • TorqVue Delivery Sheath (Range : 7, 8, 9, 10, 12Fr)
  • Device = PFO OCCLUDERS (Range : 18, 25, 35 mm)
  • Sizing balloon (18, 24)

Pericardiocentesis (Standby)

  • Pericardiocentesis tray

Device Thrombosis/Retrieval Supplies

  • 16 or 18 Fr Dry Seal Sheath
  • 6 or 7 Fr Ensnare Kit or Gooseneck Snare



PERICARDIOCENTESIS

Not DD or CS

Call Echo

  • Micropuncture
  • 75 Amplatz SS
  • Pericardiocentesis tray
  • Accordion drain bag

Spies

Call Echo

Supplies:

  • Micro puncture
  • 150cm J wire
  • 4/5fr slender sheath
  • 5fr straight pigtail diagnostic
  • gravity drainage bag
  • brown reservoir lab canister
  • Two 50 or 60ml syringes


Daniels

Call Echo

Supplies

Open

Emergency Kit located in each lab containing the following items:

  • Eye drape
  • Skater introducer set
  • Bard locking pigtail (6f or 8f)
  • (3) 60ml luer lock syringe
  • Amplatz super stiff .035 180cm wire
  • Probe cover
  • Stopcock
  • Accordion drainage bag

Standby

  • Chiba biopsy needle 10cm 18g
  • Standard .035 150cm j wire

Device Thrombosis/Retrieval Supplies

  • 16 or 18 Fr Dry Seal Sheath
  • 6 or 7 Fr Ensnare Kit or Gooseneck Snare



Approved: MM/YY