Port Placement / Removal: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
 
Line 9: Line 9:
*Fluoro drape  
*Fluoro drape  
*Turtle shell cover  
*Turtle shell cover  
*Light handle cover
*<nowiki>#</nowiki>15 Blade  
*<nowiki>#</nowiki>15 Blade  
*Raytex  
*Raytex  
Line 23: Line 24:
*Stratafix 3.0 & Stratafix 4.0 (or ask)  
*Stratafix 3.0 & Stratafix 4.0 (or ask)  
*No dressing, leave it open.
*No dressing, leave it open.
*Syringe->tubing->Tunneler->0
*Syringe->0->tubing->Tunneler
*Cap on tubing, port will be at zero
*Cap on tubing, port will be at zero
Tunnel north, then attach port
 
#Micropuncture and wire
#Pocket
#Tunnel north
#.035 wire -> peel away
#Catheter goes in
#Pullback under fluoro and cut
#Hookup and close
 


==Dare==
==Dare==

Latest revision as of 17:32, 18 November 2024

PORT PLACEMENT/REMOVAL

  • Heparinized Saline 1000 ml

Supplies

  • Angio pack
  • Micro puncture Kit
  • Probe cover
  • Fluoro drape
  • Turtle shell cover
  • Light handle cover
  • #15 Blade
  • Raytex
  • Sutures (see MD preference below)
  • Pickups
  • Exofin
  • Ioban
  • 8Fr Powerport (check with MD)


Bronzo

  • Do not connect catheter on the port
  • Stratafix 3.0 & Stratafix 4.0 (or ask)
  • No dressing, leave it open.
  • Syringe->0->tubing->Tunneler
  • Cap on tubing, port will be at zero
  1. Micropuncture and wire
  2. Pocket
  3. Tunnel north
  4. .035 wire -> peel away
  5. Catheter goes in
  6. Pullback under fluoro and cut
  7. Hookup and close


Dare

  • 3-0 Vicryl
  • Connect catheter to the port
  • No dressing, leave it open


Raj

  • Flow switch
  • 3-0 Vicryl
  • Connect catheter to the port
  • Steri strips for incision site (cut small) for post dressing


Brittany

  • 3.0 Vicryl
  • 4-0 PS-2 Coated Vicryl
  • Connect catheter to the port
  • No dressing, leave it open


Evan

  • Micropuncture kit (Cook)


Samir

Lynne

  • 3-0 Vicryl
  • ¼” Steri strips for post dressing
  • Cope wire
  • Connect catheter to port
  • Measure wire


If leaving accessed

  • Two IV blue caps
  • Biopatch
  • Slit gauze
  • 4x4 gauze


PORT REMOVAL

  • Angio pack
  • Raytex
  • 3-0 Vicryl
  • 4-0 Vicryl
  • #15 Blade
  • Pickups
  • Exofin
  • Ioban


Bronzo

No dressing likes to leave it open.


Dare

  • Use telfa and medium tegaderm for dressing.


Raj

Brittany

  • No dressing, leave it open


Evan

Samir

Lynne