Port Placement / Removal: Difference between revisions
From Bay Area Structural Heart Wiki
(Created page with " ==Procedure Name== {| class="wikitable" !colspan="3"|Short Procedure Name |- !Anesthesia !Imaging !Access |- |General |Fluoro and TEE | *Femoral Vein x2 *Femoral Artery x1 |- ! colspan="3" |Pre-Procedure Watchouts |- |colspan="3" |* ''' Tidal volume during time-out! ''' |- |} ===Main Header e.g. wires,sheaths:=== ====Open==== * ITEMS TO ALWAYS OPEN * (2) Items in ALL CAPS * (quantity) ITEM ====Standby==== * STANDBY ITEMS * GO HERE ==Procedure== *Bullet list o...") |
(→Bronzo) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
PORT PLACEMENT/REMOVAL | |||
*Heparinized Saline 1000 ml | |||
==Supplies== | |||
*Angio pack | |||
*Micro puncture Kit | |||
*Probe cover | |||
*Fluoro drape | |||
*Turtle shell cover | |||
*<nowiki>#</nowiki>15 Blade | |||
*Raytex | |||
*Sutures (see MD preference below) | |||
*Pickups | |||
*Exofin | |||
*Ioban | |||
*8Fr Powerport (check with MD) | |||
==Bronzo== | |||
*Do not connect catheter on the port | |||
*Stratafix 3.0 & Stratafix 4.0 (or ask) | |||
*No dressing, leave it open. | |||
*Syringe->tubing->Tunneler->0 | |||
*Cap on tubing, port will be at zero | |||
Tunnel north, then attach port | |||
==Dare== | |||
*3-0 Vicryl | |||
*Connect catheter to the port | |||
*No dressing, leave it open | |||
==Raj== | |||
*Flow switch | |||
*3-0 Vicryl | |||
*Connect catheter to the port | |||
*Steri strips for incision site (cut small) for post dressing | |||
==Brittany== | |||
*3.0 Vicryl | |||
*4-0 PS-2 Coated Vicryl | |||
*Connect catheter to the port | |||
*No dressing, leave it open | |||
==Evan== | |||
*Micropuncture kit (Cook) | |||
==Samir== | |||
==Lynne== | |||
*3-0 Vicryl | |||
*¼” Steri strips for post dressing | |||
*Cope wire | |||
*Connect catheter to port | |||
*Measure wire | |||
===If leaving accessed=== | |||
*Two IV blue caps | |||
*Biopatch | |||
*Slit gauze | |||
*4x4 gauze | |||
==PORT REMOVAL== | |||
*Angio pack | |||
*Raytex | |||
*3-0 Vicryl | |||
*4-0 Vicryl | |||
*<nowiki>#</nowiki>15 Blade | |||
*Pickups | |||
*Exofin | |||
*Ioban | |||
==Bronzo== | |||
No dressing likes to leave it open. | |||
==Dare== | |||
*Use telfa and medium tegaderm for dressing. | |||
==Raj== | |||
==Brittany== | |||
*No dressing, leave it open | |||
=== | ==Evan== | ||
== | ==Samir== | ||
==Lynne== | |||
[[Category:IRProcedures]] | [[Category:IRProcedures]] |
Latest revision as of 17:47, 11 November 2024
PORT PLACEMENT/REMOVAL
- Heparinized Saline 1000 ml
Supplies
- Angio pack
- Micro puncture Kit
- Probe cover
- Fluoro drape
- Turtle shell cover
- #15 Blade
- Raytex
- Sutures (see MD preference below)
- Pickups
- Exofin
- Ioban
- 8Fr Powerport (check with MD)
Bronzo
- Do not connect catheter on the port
- Stratafix 3.0 & Stratafix 4.0 (or ask)
- No dressing, leave it open.
- Syringe->tubing->Tunneler->0
- Cap on tubing, port will be at zero
Tunnel north, then attach port
Dare
- 3-0 Vicryl
- Connect catheter to the port
- No dressing, leave it open
Raj
- Flow switch
- 3-0 Vicryl
- Connect catheter to the port
- Steri strips for incision site (cut small) for post dressing
Brittany
- 3.0 Vicryl
- 4-0 PS-2 Coated Vicryl
- Connect catheter to the port
- No dressing, leave it open
Evan
- Micropuncture kit (Cook)
Samir
Lynne
- 3-0 Vicryl
- ¼” Steri strips for post dressing
- Cope wire
- Connect catheter to port
- Measure wire
If leaving accessed
- Two IV blue caps
- Biopatch
- Slit gauze
- 4x4 gauze
PORT REMOVAL
- Angio pack
- Raytex
- 3-0 Vicryl
- 4-0 Vicryl
- #15 Blade
- Pickups
- Exofin
- Ioban
Bronzo
No dressing likes to leave it open.
Dare
- Use telfa and medium tegaderm for dressing.
Raj
Brittany
- No dressing, leave it open