Christian Spies M.D.: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
No edit summary
 
(22 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Physician
{{Physician
|Glove size=8
|Glove size=8
|Access=U/s and micropuncture
|Access=U/s for all access, Keep probe on field like PH does. Wet blue towel on pts. Lap.
|Radial Setup=4/5 dx only, 5/6 pci, JL3.5 / JR4
|Radial Setup=5/6 Slender and 5 F JL3.5 / JR4
|Radial Cocktail=2.5mg Verapamil (in 1 or 3cc syringe), 5000u Heparin, He will mix
|Radial Cocktail=2.5mg Verapamil (in 1 or 3cc syringe), 5000u Heparin, No nitro on table.,Nitro on standby. ,Ok to mix verap and heparin
|Groin Setup=6fr sheath, JL4 / JR4
|Groin Setup=6fr sheath, JL4 / JR4
|Closure Device=Perclose
|Closure Device=Perclose
|Right Heart Setup=Brachial if there is an IV IF NOT prep neck, MANIFOLD ONLY, NO ACIST FOR RHC, 6F BALLOON WEDGE IF NO TDCO NEEDED, 6F balloon wedge for Triluminate.
|Intervention Setup=Minamo
|Phone Number=1-415-707-9939
|Phone Number=1-415-707-9939
|Interventional Wire=Minamo
}}
}}
If post transplant, 6fr sheath, 6fr guide, Runthrough wire, IVUS.  If radial for LHC, brachial 5fr sheath, 5fr swan (post transplant follow up). All right heart procedures are to be done with a manifold, not the Acist.
===No Acist for Right heart procedures, manifold only!===
===Prefers Minamo wire for intervention===
==Post Transplant LHC with IVUS==
===Groin===
*6fr. Sheath
*6fr. Guide
*Runthrough
*IVUS catheter
 
===Radial===
*Same with radial sheath
*6fr. Brachial
*6fr. PA catheter
 
==AS screening cases==
*6fr. Radial
*7fr. Brachial
*Langston catheter
*Dual manifold transducers
*7fr. Swan for TDCO
*Straight .035 to cross

Latest revision as of 18:41, 6 November 2024


Glove size 8
Access
  • U/s for all access
  • Keep probe on field like PH does. Wet blue towel on pts. Lap.
Radial Setup
  • 5/6 Slender and 5 F JL3.5 / JR4
Radial Cocktail
  • 2.5mg Verapamil (in 1 or 3cc syringe)
  • 5000u Heparin
  • No nitro on table.
  • Nitro on standby.
  • Ok to mix verap and heparin
Groin Setup
  • 6fr sheath
  • JL4 / JR4
Closure Device
  • Perclose
Right Heart Setup
  • Brachial if there is an IV IF NOT prep neck
  • MANIFOLD ONLY
  • NO ACIST FOR RHC
  • 6F BALLOON WEDGE IF NO TDCO NEEDED
  • 6F balloon wedge for Triluminate.
Intervention Setup
  • Minamo
Phone Number 1-415-707-9939
Pager Number

Edit this page

No Acist for Right heart procedures, manifold only!

Prefers Minamo wire for intervention

Post Transplant LHC with IVUS

Groin

  • 6fr. Sheath
  • 6fr. Guide
  • Runthrough
  • IVUS catheter

Radial

  • Same with radial sheath
  • 6fr. Brachial
  • 6fr. PA catheter

AS screening cases

  • 6fr. Radial
  • 7fr. Brachial
  • Langston catheter
  • Dual manifold transducers
  • 7fr. Swan for TDCO
  • Straight .035 to cross