Christian Spies M.D.: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
No edit summary
 
(11 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Physician
{{Physician
|Glove size=8
|Glove size=8
|Access=U/s for all access, Keep probe on field like PH does
|Access=U/s for all access, Keep probe on field like PH does. Wet blue towel on pts. Lap.
|Radial Setup=5/6 Slender and 5 F JL3.5 / JR4
|Radial Setup=5/6 Slender and 5 F JL3.5 / JR4
|Radial Cocktail=2.5mg Verapamil (in 1 or 3cc syringe), 5000u Heparin, He will mix
|Radial Cocktail=2.5mg Verapamil (in 1 or 3cc syringe), 5000u Heparin, No nitro on table.,Nitro on standby. ,Ok to mix verap and heparin
|Groin Setup=6fr sheath, JL4 / JR4
|Groin Setup=6fr sheath, JL4 / JR4
|Closure Device=Perclose
|Closure Device=Perclose
|Right Heart Setup=MANIFOLD ONLY. NO ACIST FOR RHC. EVER. EVER. EVER., 6F BALLOON WEDGE IF NO TDCO NEEDED, 6F balloon wedge for Triluminate.
|Right Heart Setup=Brachial if there is an IV IF NOT prep neck, MANIFOLD ONLY, NO ACIST FOR RHC, 6F BALLOON WEDGE IF NO TDCO NEEDED, 6F balloon wedge for Triluminate.
|Intervention Setup=Minamo
|Phone Number=1-415-707-9939
|Phone Number=1-415-707-9939
|Interventional Wire=Minamo
}}
}}
===No Acist for Right heart procedures, manifold only!===
===No Acist for Right heart procedures, manifold only!===
Line 22: Line 24:
*6fr. Brachial
*6fr. Brachial
*6fr. PA catheter
*6fr. PA catheter
==AS screening cases==
*6fr. Radial
*7fr. Brachial
*Langston catheter
*Dual manifold transducers
*7fr. Swan for TDCO
*Straight .035 to cross

Latest revision as of 18:41, 6 November 2024


Glove size 8
Access
  • U/s for all access
  • Keep probe on field like PH does. Wet blue towel on pts. Lap.
Radial Setup
  • 5/6 Slender and 5 F JL3.5 / JR4
Radial Cocktail
  • 2.5mg Verapamil (in 1 or 3cc syringe)
  • 5000u Heparin
  • No nitro on table.
  • Nitro on standby.
  • Ok to mix verap and heparin
Groin Setup
  • 6fr sheath
  • JL4 / JR4
Closure Device
  • Perclose
Right Heart Setup
  • Brachial if there is an IV IF NOT prep neck
  • MANIFOLD ONLY
  • NO ACIST FOR RHC
  • 6F BALLOON WEDGE IF NO TDCO NEEDED
  • 6F balloon wedge for Triluminate.
Intervention Setup
  • Minamo
Phone Number 1-415-707-9939
Pager Number

Edit this page

No Acist for Right heart procedures, manifold only!

Prefers Minamo wire for intervention

Post Transplant LHC with IVUS

Groin

  • 6fr. Sheath
  • 6fr. Guide
  • Runthrough
  • IVUS catheter

Radial

  • Same with radial sheath
  • 6fr. Brachial
  • 6fr. PA catheter

AS screening cases

  • 6fr. Radial
  • 7fr. Brachial
  • Langston catheter
  • Dual manifold transducers
  • 7fr. Swan for TDCO
  • Straight .035 to cross