Embolization: Difference between revisions
From Bay Area Structural Heart Wiki
(Created page with "EMBOLIZATION *CONFIRM WITH PHYSICIAN REGARDING CATHETERS AND USE OF INJECTOR* ***Injector set up 100% contrast for Dr Olorunsola. The rest of the MD’s are 50/50 * 100% Contrast (hand injection) unless the Physician states otherwise. *Heparinized Saline 1000 ml Angio pack Gloves Fluoro drape U/S Prober cover Turtle shell cover 5Fr x 11cm sheath 3-way stopcock Tuohy 3cc Blue Medallion syringe (2) Green or Purple Medallion syringe for contra...") |
No edit summary |
||
Line 1: | Line 1: | ||
{{Warn|CONFIRM WITH PHYSICIAN REGARDING CATHETERS AND USE OF INJECTOR}} | |||
*Injector set up 100% contrast for Dr Olorunsola. The rest of the MD’s are 50/50 | |||
*100% Contrast (hand injection) unless the Physician states otherwise. | |||
* 100% Contrast (hand injection) unless the Physician states otherwise. | |||
*Heparinized Saline 1000 ml | *Heparinized Saline 1000 ml | ||
==Open== | |||
*Angio pack | |||
Angio pack | *Gloves | ||
*Fluoro drape | |||
Gloves | *U/S Prober cover | ||
*Turtle shell cover | |||
Fluoro drape | *5Fr x 11cm sheath | ||
*3-way stopcock | |||
U/S Prober cover | *Tuohy | ||
*3cc Blue Medallion syringe | |||
Turtle shell cover | *(2) Green or Purple Medallion syringe for contrast | ||
*3J x 145cm guidewire | |||
5Fr x 11cm sheath | *Glide wire 180cm | ||
3-way stopcock | |||
Tuohy | |||
3cc Blue Medallion syringe | |||
(2) Green or Purple Medallion syringe for contrast | |||
3J x 145cm guidewire | |||
Glide wire 180cm | |||
Fathom Guidewire | Fathom Guidewire | ||
**Torque Device (if needed) | |||
Torque Device (if needed) | *One way or blue cap | ||
*(2) 12cc syringe | |||
One way or blue cap | *RIM (Postpartum bleed) | ||
*RBT catheter (Postpartum bleed) | |||
(2) 12cc syringe | |||
RIM (Postpartum bleed) | |||
RBT catheter (Postpartum bleed) | |||
==Bronzo== | |||
*SOS2 80cm catheter | |||
SOS2 80cm catheter | *STS Straight Microcatheter | ||
*Hummingbird technique (Insertion tool attach to 20cc Hep saline syringe) | |||
STS Straight Microcatheter | *Starclose (ask) | ||
Hummingbird technique (Insertion tool attach to 20cc Hep saline syringe) | |||
Starclose (ask) | |||
==Dare== | |||
*Cobra2 75cm catheter | |||
Cobra2 75cm catheter | *Hi-Flo Microcatheter | ||
*Closure device (ask) | |||
Hi-Flo Microcatheter | |||
Closure device (ask) | |||
==Raj== | |||
*Shape guidewire himself | |||
Flow switch | ===Open=== | ||
*Flow switch | |||
Bentson guidewire | *Bentson guidewire | ||
*Hummingbird technique (cut micro puncture dilator and attach to 20cc Hep saline syringe) | |||
*Extra Prep stick (closure) | |||
*Mynx | |||
Hummingbird technique (cut micro puncture dilator and attach to 20cc Hep saline syringe) | *Omniflush (Postpartum Bleed) | ||
Extra Prep stick (closure) | |||
Mynx | |||
Omniflush (Postpartum Bleed) | |||
Line 92: | Line 56: | ||
BRITTANY: | BRITTANY: | ||
*Always set up Injector | |||
===Open=== | |||
*Starclose | |||
Always set up Injector | *C2 catheter (for Liver Embo) | ||
*Renegade HiFlo micro catheter | |||
C2 catheter (for Liver Embo) | *Fathom wire | ||
*Extra Prep stick for closure | |||
Renegade HiFlo micro catheter | *Extra gloves for closure | ||
Fathom wire | |||
Extra Prep stick for closure | |||
Extra gloves for closure | |||
==Evan== | |||
*Micropuncture kit (Cook) | |||
==Samir== | |||
==Lynne== | |||
===Open=== | |||
*Flow switch | |||
*Hummingbird technique (cut micro puncture dilator and attach to 20cc Hep saline syringe) | |||
*Bentson guidewire | |||
*C2 catheter | |||
*2.0 Fr True Select | |||
*Synchro Soft guidewire | |||
*Extra Prep stick (closure) | |||
*Mynx | |||
===Standby=== | |||
*2.4 Fr Microcatheter | |||
*SOS 2 | |||
===Coils=== | |||
*Detacher – If using Concerto coils | |||
===Coil Deployment Steps=== | |||
#Make sure the introducer sheath is nice and hubbed (seated) in microcatheter. | |||
#Take orange lock off – discard | |||
#Start advancing wire | |||
#Remove sheath with 5-10cm left | |||
#Save sheath just in case you want to recapture coil | |||
#Dr takes over and when happy with coil – snap and pull two white markers on back end | |||
#Check under fluoro that coil is fully out of microcatheter and that nothing moves when you go to deploy. | |||
===ONYX Liquid Embolic System=== | |||
ONYX Liquid Embolic System | *Onyx 18 or Onyx 34 (Neuro cart) | ||
*Shaker machine (Neuro cart) | |||
Onyx 18 or Onyx 34 (Neuro cart) | *Need a clean surface or extra table | ||
*New gloves | |||
Shaker machine (Neuro cart) | *(2) 18G needles, one for drawing up Onyx and one for drawing up DMSO | ||
Need a clean surface or extra table | |||
New gloves | |||
(2) 18G needles, one for drawing up Onyx and one for drawing up DMSO | |||
===Obsidio=== | |||
*EP Fridge (Sterile core) | |||
EP Fridge (Sterile core) | |||
Line 228: | Line 147: | ||
*3cc Medallion syringe | *3cc Medallion syringe | ||
*Postpartum Bleed – 20cc syringe with 7ml of contrast attach to 10cc syringe with gel foam (mix) | *Postpartum Bleed – 20cc syringe with 7ml of contrast attach to 10cc syringe with gel foam (mix) | ||
Revision as of 22:43, 5 November 2024
Warning: CONFIRM WITH PHYSICIAN REGARDING CATHETERS AND USE OF INJECTOR
- Injector set up 100% contrast for Dr Olorunsola. The rest of the MD’s are 50/50
- 100% Contrast (hand injection) unless the Physician states otherwise.
- Heparinized Saline 1000 ml
Open
- Angio pack
- Gloves
- Fluoro drape
- U/S Prober cover
- Turtle shell cover
- 5Fr x 11cm sheath
- 3-way stopcock
- Tuohy
- 3cc Blue Medallion syringe
- (2) Green or Purple Medallion syringe for contrast
- 3J x 145cm guidewire
- Glide wire 180cm
Fathom Guidewire
- Torque Device (if needed)
- One way or blue cap
- (2) 12cc syringe
- RIM (Postpartum bleed)
- RBT catheter (Postpartum bleed)
Bronzo
- SOS2 80cm catheter
- STS Straight Microcatheter
- Hummingbird technique (Insertion tool attach to 20cc Hep saline syringe)
- Starclose (ask)
Dare
- Cobra2 75cm catheter
- Hi-Flo Microcatheter
- Closure device (ask)
Raj
- Shape guidewire himself
Open
- Flow switch
- Bentson guidewire
- Hummingbird technique (cut micro puncture dilator and attach to 20cc Hep saline syringe)
- Extra Prep stick (closure)
- Mynx
- Omniflush (Postpartum Bleed)
BRITTANY:
- Always set up Injector
Open
- Starclose
- C2 catheter (for Liver Embo)
- Renegade HiFlo micro catheter
- Fathom wire
- Extra Prep stick for closure
- Extra gloves for closure
Evan
- Micropuncture kit (Cook)
Samir
Lynne
Open
- Flow switch
- Hummingbird technique (cut micro puncture dilator and attach to 20cc Hep saline syringe)
- Bentson guidewire
- C2 catheter
- 2.0 Fr True Select
- Synchro Soft guidewire
- Extra Prep stick (closure)
- Mynx
Standby
- 2.4 Fr Microcatheter
- SOS 2
Coils
- Detacher – If using Concerto coils
Coil Deployment Steps
- Make sure the introducer sheath is nice and hubbed (seated) in microcatheter.
- Take orange lock off – discard
- Start advancing wire
- Remove sheath with 5-10cm left
- Save sheath just in case you want to recapture coil
- Dr takes over and when happy with coil – snap and pull two white markers on back end
- Check under fluoro that coil is fully out of microcatheter and that nothing moves when you go to deploy.
ONYX Liquid Embolic System
- Onyx 18 or Onyx 34 (Neuro cart)
- Shaker machine (Neuro cart)
- Need a clean surface or extra table
- New gloves
- (2) 18G needles, one for drawing up Onyx and one for drawing up DMSO
Obsidio
- EP Fridge (Sterile core)
Embospheres
Protip: Make sure to let the beads settle against the plunger before wasting extra liquid
- 100 - 300
- 300 – 500
- 500 – 700
- 700 – 900
- (2) 1cc White Medallion syringe, for bead injection
- (2) 10cc syringes with contrast (100%)
- 3-way stopcock
Trufil Glue
- Clean surface or extra table
- ¾ sheet (if using a separate table)
- 5% Dextrose 500ml saline bag
Blue bowl
- Medicine cup (Overstock cart – sterile core)
- Gloves
- (2) White 1cc medallion syringe
- (2) 20cc syringes
- (3) 3cc syringes
- (3) 6cc syringes
- (2) 18G needle
GEL FOAM
- Pharmacy cart (ask RN)
- 3-way stopcock
- 10cc syringe
- 6cc syringe
- 3cc Medallion syringe
- Postpartum Bleed – 20cc syringe with 7ml of contrast attach to 10cc syringe with gel foam (mix)