{{Warn|CONFIRM WITH PHYSICIAN REGARDING CATHETERS, USE OF INJECTOR}} | {{Warn|CONFIRM WITH PHYSICIAN REGARDING CATHETERS, USE OF INJECTOR}} | ||
*Injector set up 100% contrast for Dr Olorunsola. The rest of the MD’s are 50/50 Concentration *100% Contrast (hand injection) unless the Physician states otherwise. | *Injector set up 100% contrast for Dr Olorunsola. The rest of the MD’s are 50/50 Concentration | ||
*100% Contrast (hand injection) unless the Physician states otherwise. | |||
*Heparinized Saline 1000 ml | *Heparinized Saline 1000 ml | ||
Line 109: | Line 111: | ||
===Standby=== | ===Standby=== | ||
SOS2 catheter | SOS2 catheter | ||
[[Category::IRProcedures]] |
Latest revision as of 21:54, 5 November 2024
Warning: CONFIRM WITH PHYSICIAN REGARDING CATHETERS, USE OF INJECTOR
- Injector set up 100% contrast for Dr Olorunsola. The rest of the MD’s are 50/50 Concentration
- 100% Contrast (hand injection) unless the Physician states otherwise.
- Heparinized Saline 1000 ml
Supplies
- ¾ sheet (floor covering)
- Shoe covers for all staff
Open onto table
- Angio pack
- Gloves
- Fluoro drape
- U/S Probe cover
- Turtle shell cover
- 5Fr x 11cm sheath
- 3-way stopcock
- Tuohy
- 12” extension tubing
- 3cc Blue Medallion syringe
- (2) 3cc Green or Purple Medallion syringe for contrast
- 3J x 145cm guidewire
- Glide wire 180cm
- Torque Device (if needed)
- Fathom Guidewire
- One way or blue cap for end of tuohy
- (2) 12cc syringe
- ¾ sheet (for table)
Mayo stand for Administration set
- Therasphere Equipment box (storage room)
- Therasphere administration set
- Saline 250ml
- Sterile Gloves
- Towels
- 4x4 gauze
- Suture removal kit
- Small tegaderm
- Alcohol wipes
Administration Set Priming
- Open the Administration Set
- Connect the non-vented spike to the saline, and hang saline on hook
- Connect the vented spike (near label “A”) to the empty glass vial
- Remove the red rubber cap, keeping the needle injector tip sterile
- Prime the Administration Set tubing and syringe with saline. You will see 2 streams of saline flowing continuously from the needle injector holes
- Continue priming until bubbles are removed and saline flows continuously out of both needle holes of the injector
- After priming, red rubber cap may be reinstalled to keep the tip sterile
- Fill the syringe when priming is complete
Bronzo
- SOS2 80cm catheter
- STC Straight Microcatheter
- Hummingbird technique (Insertion tool attach to 20cc Hep saline syringe)
- Starclose (ask)
Dare
- Cobra2 75cm catheter
- Hi-Flo Microcatheter
- 12” extension tubing
- 3-way stopcock
- Closure device (ask)
Raj
- Flow switch
- Shape guidewire himself
- Hummingbird technique (cut micro puncture dilator and attach to 20cc Hep saline syringe)
- Bentson wire
- Mynx
Brittany
- Always set up injector
- Starclose
- Tuohy
- C2 catheter
- Renegade Hi Flo
- Fathom wire
- Extra Prep stick
- New gloves for closure
Evan
- Micropuncture kit (Cook)
Samir
Lynne
- Flow switch
- Bentson guidewire
- C2 catheter
- 2.4Fr Microcatheter
- Synchro Soft guidewire 215cm
- 2.0Fr True Select & Synchro Soft guidewire – FOR TREATMENT
- Hummingbird technique (cut micro puncture dilator and attach to 20cc Hep saline syringe)
- RADPAD
- Extra Prep stick
- Mynx
Standby
SOS2 catheter