TAVI - Sapien 3 (Edwards): Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
 
(14 intermediate revisions by 3 users not shown)
Line 1: Line 1:
'''Transcatheter Aortic Valve Repair''' ([[wikipedia:Percutaneous_aortic_valve_replacement|Wikipedia]]) procedures utilize a femoral approach to deliver a stent-based aortic valve to the patients heart. There are two valve types available:
'''Transcatheter Aortic Valve Repair''' ([[wikipedia:Percutaneous_aortic_valve_replacement|Wikipedia]])  


*[https://www.medtronic.com/us-en/healthcare-professionals/therapies-procedures/cardiovascular/transcatheter-aortic-valve-replacement.html CoreValve by Medtronic] - [[TAVR - CoreValve (Medtronic)|CoreValve Procedure Page]]
*[https://www.medtronic.com/us-en/healthcare-professionals/therapies-procedures/cardiovascular/transcatheter-aortic-valve-replacement.html CoreValve by Medtronic] - [[TAVR - CoreValve (Medtronic)|CoreValve Procedure Page]]
*[https://www.edwards.com/gb/devices/heart-valves/transcatheter-SAPIEN-3-Ultra Sapien 3 Ultra by Edwards] - This page
*[https://www.edwards.com/gb/devices/heart-valves/transcatheter-SAPIEN-3-Ultra Sapien 3 Ultra by Edwards]  


This procedure is usually done in Room 1, and requires a 5 person team: Front table scrub, Back table scrub (device prep), Circulator, Pacer/Circulator, and Recorder. The rep for the respective company will be present to assist with device prep except in the case of an emergency valve placement.
==Daniels ==
 
In rare cases, the [[BASILICA]] procedure will be necessary to split the existing valve leaflets to prevent blockage of the coronary arteries. In that situation, the equipment on the [[BASILICA]] page will be needed in addition to the equipment listed below.
 
Per Rosalie:
 
TAVR/TMVI
 
#Edwards Sapien 3 Ultra (20, 23 & 26mm) and Sapien 3 (29mm) – scan the valve barcode (box) in McKesson for documentation and charges.  Bundle includes valve, delivery system, crimper, e sheath intro set, balloon cath & locking syringe.  With the new inventory system (POU) space is limited in entering item full description.   If pre dilatation Edwards balloon is necessary free text the balloon used in procedure notes (McKesson).
#Medtronic Core Valve – all items are charge separately.  Scan all barcodes (delivery system, loading system and valve).
 
==Daniels (Spies has his own draft) - Draft==
ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX
ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX
===Sheaths:===
===Equipment :===


*5Fr Micropunture  Kit  
*5Fr Micropunture  Kit  
Line 25: Line 14:
*(2) Cordis 150J
*(2) Cordis 150J
*Cordis 260J
*Cordis 260J
*Safari Wire  
*Safari Wire (DANIELS & SPIES)
*Amplatz Extra Stiff 1cm tip (GROVES)
*Terumo Stiff Straight Glidewire 0.035 x 150 cm
*Terumo Stiff Straight Glidewire 0.035 x 150 cm
*.035 Standard Straight for Valve-in-Valve crossing, no need for glidewire.
*Acist hand control
*Acist hand control
*(3) Perclose
*(3) Perclose
*A extension line from anesthesia (Venous extension only if we are doing bipolar pacing)
*A extension line from anesthesia (Venous extension only if we are doing bipolar pacing)
*5Fr AL1 diagnostic 
*5Fr AL1 diagnostic 
*5Fr Ang Pigtail (2 for Spies)
*(2) 5Fr Ang Pigtail  
**'''Valve-in-valve: Mosaic needs pigtail, all others do not.'''
*6Fr JL4/JR4 (when doing coronary angiography)
*6Fr JL4/JR4 (when doing coronary angiography)
*Exofin topical adhesive
*NuKnit for closure


=== Unipolar Transvenous pacing supplies ===
=== Unipolar Transvenous pacing supplies (Daniels preference) ===


* Alligator Clip Remington Pacing Cables
* Alligator Clip Remington Pacing Cables
* TZ Medical Defibrillation Pads - Found in EP pyxis in labs. Large pad utilized as a grounding pad on the patients chest (subxyphoid)
* TZ Medical Defibrillation Pads - Found in EP pyxis in labs. Large pad utilized as a grounding pad on the patients chest (subxyphoid)
* NOTE : If patient is in second degree HB please prep and drape RIJ
{{Protip|</BR>For cases where patient has an LVAD you'll need a Safari II instead of an ES</BR>
For patients with AI you don't need the Glidewire.}}


{{Protip|For AI cases you'll need a second pigtail and no AL1.}}
{{Protip|For patients with AI you don't need the Glidewire or AL1. Use second pigtail to cross. }}


=== Bipolar Transvenous pacemaker supplies ===
*5Fr Josephson Pacing catheter for DD ; 5F Abbott Pacel Balloon Flow Directed Tip Pacing catheter for CS
*Dual Red/Black Pacing Remington cables
*EP Quad Cable
*8Fr x 35 cm Brite Tip Sheath
*Amplatz Extra Stiff 260cm on standby


===Medications on table:===
===Medications on table:===
Line 57: Line 41:


*Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)
*Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)
*10 ml Rotaglide  
*10 ml Rotaglide yellow syringe
 
===Edwards:===
 
*Crimper
*Indeflator
*Appropriate delivery system and valve


=== Sentinel ===
===Standby ECMO & Pericardial Effusion supplies===


=== Sentinel: ===
* Grandslam 300cm
* Grandslam 300cm
* 5/6 Slender
* 5/6 Slender
* 2.5 Verapamil
* 2.5 Verapamil
* DSA at 6fps of aortic arch with contralateral pigtail
* DSA at 6fps of aortic arch with contralateral pigtail
* Don't open sentinel until we see the Grandslam advance thru the arm to the arch
* Don't open sentinel until we see the Grandslam advanced to the arch
* Prep instructions in lab 1 on the wall next to the light switches
* Prep instructions in lab 1 on the wall next to the light switches


Line 75: Line 66:


*22G Grey Lido needle for Spies
*22G Grey Lido needle for Spies
===Edwards:===
*Crimper
*Indeflator
**23-26 - 2530 for up to 26+2
**29 - 38
*Appropriate delivery system and valve
===Standby ECMO & Pericardial Effusion supplies===


==Procedure==
==Procedure==
Line 94: Line 75:
* Patient prepped from naval to mid thigh using chlorahexidine soap followed by chloraprep with 3 minute dry time.  
* Patient prepped from naval to mid thigh using chlorahexidine soap followed by chloraprep with 3 minute dry time.  
* Towel off site. Extend Femoral drape all the way to chin.  
* Towel off site. Extend Femoral drape all the way to chin.  
* Fluoro cover used to drape anesthesia's IV pole/x-ray shield.
* Extension tubing for anesthesia flushed and secured on respecitve sides of the groin .
* Extension tubing for anesthesia flushed and secured on respecitve sides of the groin .
* Dual pressure lines primed and zeroed prior to case start.


'''FRONT TABLE'''
'''FRONT TABLE'''


* 50/50 Lido and Bupivicaine mix used for local anesthetic.  Have extra available on front table.
* 50/50 Lido and Bupivacaine mix used for local anesthetic.  Have extra available on front table.
* 100% contrast available on table. (May need for hand injection or for peripheral balloon prep)
* 1-1.5 L of Hep Saline in large bowl
* 10ml of Rotoglide on table (Attached to E sheath with a 20ml flush of hep saline)
* 10ml of Rotaglide on table (Attached to E sheath)
* 10ml syringe of Epi taped on table.
* 10ml syringe of Epi on table.
* U/S guidance for groin access
* U/S guidance for groin access


'''BACK TABLE'''- valve prep
'''BACK TABLE'''- valve prep


* 4 Bowls: (2) Normal Saline (1) Hep Saline (1) '''30ml contrast, 170ml Hep Saline mix (15%)'''
* 3 Bowls: (1) Normal Saline (500ml in each bowl)  (1) Hep Saline (500ml) (1) 30ml contrast (170ml Hep Saline added to by scrub person to make it 15%)
* 20 ml of contrast in cup (100% contrast available on table. May need for hand injection or for peripheral balloon prep)
* 60ml Syringe with contrast mixture for balloon prep.  
* 60ml Syringe with contrast mixture for balloon prep.  
* 20ml Syringe for flushing delivery system
* 20ml Syringe for flushing delivery system
* Indeflator: volume dependent upon valve size
* Indeflator: volume dependent upon valve size
* Crimper
* Crimper
* Hemostats and scissors for valve opening
* High pressure stopcock
* High pressure stopcock


Line 124: Line 103:


*Pigtail -> LFA -> AO root injection
*Pigtail -> LFA -> AO root injection
**Standard Injector settings (adjusted based on pt and root size)
**Standard Injector settings '''10/10 20mm valve, 15/15 23mm and 26mm valve, 20/20 29mm valve'''
 
'''10/10 20mm valve, 15/15 23mm and 26mm valve, 20/20 29mm valve'''


*AL1 advanced through 8F sheath over standard J.
*AL1 advanced through 8F sheath over standard J.
*Standard J removed and crossing wire advanced. Cross valve. Wire removed.
*Standard J removed and crossing wire advanced. Cross valve. Wire removed.
*Measure gradient...maybe
*Measure EDP and gradient.
*8F sheath removed and E Sheath advanced.
*8F sheath removed and E Sheath advanced.
*Insert valve delivery system
*Insert valve delivery system
*Test pacer, black alligator clip on back of wire. Rapid pace 160, check for capture, 220 burst
*Test pacer, black alligator clip on back of wire.  
*'''Pacing : Unipolar Pacing - pace 120 - 180 , V max output 20ma. "Dial up to 180, dial down to 120, per MD request"'''
*'''Pacing : Bipolar pacing - pace 160 with 220 burst , A max output 25ma, set RAP to 220.'''
*Multiple AO grams for positioning
*Multiple AO grams for positioning
*Pace -> AO gram ->  Pigtail pulled back -> Deploy valve
*Pace -> AO gram ->  Pigtail pulled back -> Deploy valve
Line 152: Line 131:
*Pigtail pulled back to iliac bifurcation and subtracted iliac angio performed (6/18 on Acist)
*Pigtail pulled back to iliac bifurcation and subtracted iliac angio performed (6/18 on Acist)
*Pigtail removed
*Pigtail removed
*Secondary access Perclosed
*Secondary access Perclose
*Dermabond all access sites, no dressing needed.  
*Exofin all access sites, no dressing needed.
===''THE SPIES TAVR EXPERIENCE''===
 
====Product substitution====
== ''THE SPIES TAVR EXPERIENCE'' ==
*2 Pigtails
 
*Balloon-tipped PACEL pacer
====Equipment: ====
*Straight steel .035 wire (NO straight stiff glide)
 
*Supracore
* 5Fr Micropunture  Kit  
* 6Fr x 10cm sheath
* 8Fr x 10 cm sheath
* 8Fr x 35 cm Brite Tip Sheath
* (2) Cordis 150J
* Cordis 260J
* 2 Perclose
* 2 Pigtails
* Straight steel .035 wire (NO straight stiff glide)
* Amplatz ES for sheath advancement
* Safari
* 5F Abbott Pacel Balloon Flow Directed Tip Pacing catheter for CS
*Dual Red/Black Pacing Remington cables
*EP Quad Cable


====Procedural Differences====
====Procedural Differences====
*E Sheath in right after pre-closure over Supracore
*E Sheath in right after pre-closure over Supracore  
*Amplatz ES removed after E sheath insertion. AL1 advanced with J wire backloaded.
*AL1 advanced with J wire backloaded.
*After valve crossing, EXCHANGE J inserted, AL1 removed and SECOND PIGTAIL advanced. Amplatz ES advanced through pigtail and pigtail removed.
*After valve crossing, EXCHANGE J inserted, AL1 removed and SECOND PIGTAIL advanced.  
*Have IM available for iliac angiogram.
*Safari advanced through pigtail and pigtail removed.
*Iliac angio 6/18ml
*Iliac angio 6/18ml
*Lido with EPI at end of case  
*Lido with EPI at end of case  


==='''''AGRAWAL SPECIAL'''''===
== ''THE GROVES TAVI EXPERIENCE'' ==
 
===== Product Substitute =====
 
* 2 pigtails
* Amplatz ES 1CM tip
* Balloon-tipped Abbott Pacer


== '''''AGRAWAL SPECIAL''''' ==
*All accesses with mircopuncture
*All accesses with mircopuncture
*2 Percloses on primary access site
*2 Percloses on primary access site

Latest revision as of 16:49, 1 November 2024

Transcatheter Aortic Valve Repair (Wikipedia)

Daniels

ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX

Equipment :

  • 5Fr Micropunture  Kit  
  • 6Fr x 10cm sheath
  • 8Fr x 10 cm sheath
  • (2) Cordis 150J
  • Cordis 260J
  • Safari Wire (DANIELS & SPIES)
  • Amplatz Extra Stiff 1cm tip (GROVES)
  • Terumo Stiff Straight Glidewire 0.035 x 150 cm
  • .035 Standard Straight for Valve-in-Valve crossing, no need for glidewire.
  • Acist hand control
  • (3) Perclose
  • A extension line from anesthesia (Venous extension only if we are doing bipolar pacing)
  • 5Fr AL1 diagnostic 
  • (2) 5Fr Ang Pigtail
    • Valve-in-valve: Mosaic needs pigtail, all others do not.
  • 6Fr JL4/JR4 (when doing coronary angiography)
  • Exofin topical adhesive
  • NuKnit for closure

Unipolar Transvenous pacing supplies (Daniels preference)

  • Alligator Clip Remington Pacing Cables
  • TZ Medical Defibrillation Pads - Found in EP pyxis in labs. Large pad utilized as a grounding pad on the patients chest (subxyphoid)

Note Protip: For patients with AI you don't need the Glidewire or AL1. Use second pigtail to cross.


Medications on table:

  • Lido/Bupivicaine 50/50
  • Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)
  • 10 ml Rotaglide yellow syringe

Edwards:

  • Crimper
  • Indeflator
  • Appropriate delivery system and valve

Standby ECMO & Pericardial Effusion supplies

Sentinel:

  • Grandslam 300cm
  • 5/6 Slender
  • 2.5 Verapamil
  • DSA at 6fps of aortic arch with contralateral pigtail
  • Don't open sentinel until we see the Grandslam advanced to the arch
  • Prep instructions in lab 1 on the wall next to the light switches

For coronary protection:

  • Radial access OR 12F dryseal in LFA if using sentinel
  • 6F JL4
  • Runthrough
  • coronary balloon on md request
  • 22G Grey Lido needle for Spies

Procedure

SEE BELOW FOR STEPS SPECIFIC TO SPIES and AGRAWAL

  • Patient on defib pads. IF PATIENT HAS ICD: DEVICE DISABLED FOR PROCEDURE, COMPANY REP PRESENT IF POSSIBLE.
  • Leg strap secured above knees. Wrists restrained.
  • Patient prepped from naval to mid thigh using chlorahexidine soap followed by chloraprep with 3 minute dry time.
  • Towel off site. Extend Femoral drape all the way to chin.
  • Extension tubing for anesthesia flushed and secured on respecitve sides of the groin .

FRONT TABLE

  • 50/50 Lido and Bupivacaine mix used for local anesthetic. Have extra available on front table.
  • 1-1.5 L of Hep Saline in large bowl
  • 10ml of Rotaglide on table (Attached to E sheath)
  • 10ml syringe of Epi on table.
  • U/S guidance for groin access

BACK TABLE- valve prep

  • 3 Bowls: (1) Normal Saline (500ml in each bowl) (1) Hep Saline (500ml) (1) 30ml contrast (170ml Hep Saline added to by scrub person to make it 15%)
  • 20 ml of contrast in cup (100% contrast available on table. May need for hand injection or for peripheral balloon prep)
  • 60ml Syringe with contrast mixture for balloon prep.
  • 20ml Syringe for flushing delivery system
  • Indeflator: volume dependent upon valve size
  • Crimper
  • High pressure stopcock

PROCEDURE STEPS

  • Contralateral arterial access - 6fr. Sheath (normally LFA) using micropuncture. Verify wire position with fluoro and save an image.
  • Primary access - with micropuncture. Verify wire position with fluoro and save an image
    • Pre-close x 1, sutures secured with hemostat.
    • 8F sheath reconstituted and advanced after pre-closure.
  • Pigtail -> LFA -> AO root injection
    • Standard Injector settings 10/10 20mm valve, 15/15 23mm and 26mm valve, 20/20 29mm valve
  • AL1 advanced through 8F sheath over standard J.
  • Standard J removed and crossing wire advanced. Cross valve. Wire removed.
  • Measure EDP and gradient.
  • 8F sheath removed and E Sheath advanced.
  • Insert valve delivery system
  • Test pacer, black alligator clip on back of wire.
  • Pacing : Unipolar Pacing - pace 120 - 180 , V max output 20ma. "Dial up to 180, dial down to 120, per MD request"
  • Pacing : Bipolar pacing - pace 160 with 220 burst , A max output 25ma, set RAP to 220.
  • Multiple AO grams for positioning
  • Pace -> AO gram -> Pigtail pulled back -> Deploy valve
    • Cine length set at 40 seconds or more
  • TTE

if post dilation is needed...

Rep will come up and re-prep valve, adding desired amount of additional volume

If Safari was pulled back, recross wire will be needed (260cm angled stiff glide)

  • Pigtail readvanced to AO for AO gram (15/30 standard injection)
  • Safari exchanged for 260 J
  • Delivery system removed
    • Have second perclose, tools and dilator ready
  • Protamine given, Preclosures completed, manual pressure for 5ish minutes
  • Pigtail pulled back to iliac bifurcation and subtracted iliac angio performed (6/18 on Acist)
  • Pigtail removed
  • Secondary access Perclose
  • Exofin all access sites, no dressing needed.

THE SPIES TAVR EXPERIENCE

Equipment:

  • 5Fr Micropunture  Kit  
  • 6Fr x 10cm sheath
  • 8Fr x 10 cm sheath
  • 8Fr x 35 cm Brite Tip Sheath
  • (2) Cordis 150J
  • Cordis 260J
  • 2 Perclose
  • 2 Pigtails
  • Straight steel .035 wire (NO straight stiff glide)
  • Amplatz ES for sheath advancement
  • Safari
  • 5F Abbott Pacel Balloon Flow Directed Tip Pacing catheter for CS
  • Dual Red/Black Pacing Remington cables
  • EP Quad Cable

Procedural Differences

  • E Sheath in right after pre-closure over Supracore
  • AL1 advanced with J wire backloaded.
  • After valve crossing, EXCHANGE J inserted, AL1 removed and SECOND PIGTAIL advanced.
  • Safari advanced through pigtail and pigtail removed.
  • Iliac angio 6/18ml
  • Lido with EPI at end of case

THE GROVES TAVI EXPERIENCE

Product Substitute
  • 2 pigtails
  • Amplatz ES 1CM tip
  • Balloon-tipped Abbott Pacer

AGRAWAL SPECIAL

  • All accesses with mircopuncture
  • 2 Percloses on primary access site
  • .035 Standard Straight wire for valve crossing
  • After valve crossing, EXCHANGE J inserted, AL1 removed and SECOND PIGTAIL advanced. Amplatz ES advanced through pigtail and pigtail removed.
  • Amplatz ES to exchange 8F for E sheath

PERIPHERAL BAILOUT EQUIPMENT

  • Have everything available in the room, but verify items prior to opening.
  • 5F Rim Catheter
  • 6F or 7F Destination RDC
  • Exchange length Glidewire advantage
  • Exchange length angled glidewire
  • Supracore wire
  • Mustang balloons on 75cm shaft (6mm to 10mm x 40mm)
  • Viabahn stents

Approved: MM/YY