== Equipment: Spies ==
== Equipment: Spies ==
* Indiflator
* Indeflator
* Naked 3 port manifold for LA pressure
* Naked 3 port manifold for LA pressure
* Amplatz SuperStiff 1cm Tip 260cm
*5F MPA2
===* NEW - Baylis Transseptal===
===* NEW - Baylis Transseptal===
* VersaCross system
* VersaCross system
Line 39: Line 36:


*.032 X 260 “J” wire
*.032 X 260 “J” wire
*SuperStiff 1cm Tip 260cm
*5F MPA2
===Procedure requires Baylis===
===Procedure requires Baylis===
*Baylis generator
*Baylis generator
Line 45: Line 44:
===Balloon size determined by MD.===  
===Balloon size determined by MD.===  
*Sheath size determined by balloon. Balloon volume listed on Structural Heart Cart, and chart above.
*Sheath size determined by balloon. Balloon volume listed on Structural Heart Cart, and chart above.
*Have a 22 Tyshak nucleus on standby for Spies and Daniels  
*Have a 22 True balloon on standby for Spies and Daniels
<br />
<br />
<hr />
<hr />
Approved: MD initials MM/YY
Approved: MD initials MM/YY
[[Category:Procedures]]
[[Category:Procedures]]

Latest revision as of 19:40, 11 October 2024

Z-Med Inflation Chart
Other Balloons Inflation Chart

An atrial Septostomy is performed in the setting of ECMO when there is a concern that Left Atrial pressures are high due to the ECMO flow. Generally done in the setting of ECMO. It can be a stand alone procedure if not performed when ECMO is initiated.

Equipment: Daniels

  • Indiflator
  • Naked 3 port manifold for LA pressure
  • Sheath , one French size larger then minimum balloon size
  • Balloon, size determined via ECHO

* NEW - Baylis Transseptal

  • VersaCross system
  • Grounding pad

STANDBY!

  • SL1 TransSeptal sheath
  • Large curve Baylis needle
  • Baylis cable
  • .032 X 260 “J” wire
  • Amplatz SuperStiff 1cm Tip 260cm
  • 5F MPA2

Equipment: Spies

  • Indeflator
  • Naked 3 port manifold for LA pressure

* NEW - Baylis Transseptal

  • VersaCross system
  • Grounding pad

STANDBY!

  • SL1 TransSeptal sheath
  • Large curve Baylis needle
  • Baylis cable
  • .032 X 260 “J” wire
  • SuperStiff 1cm Tip 260cm
  • 5F MPA2

Procedure requires Baylis

  • Baylis generator
  • Grounding Pad

Balloon size determined by MD.

  • Sheath size determined by balloon. Balloon volume listed on Structural Heart Cart, and chart above.
  • Have a 22 True balloon on standby for Spies and Daniels



Approved: MD initials MM/YY