Peter Hui M.D.: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
|||
(7 intermediate revisions by 3 users not shown) | |||
Line 3: | Line 3: | ||
|Access=U/S and micropuncture | |Access=U/S and micropuncture | ||
|Radial Setup=5/6 Slender, Cope mandril, Rosen 260, Wholey on standby, 6fr. JL3.5 / JR4 | |Radial Setup=5/6 Slender, Cope mandril, Rosen 260, Wholey on standby, 6fr. JL3.5 / JR4 | ||
|Radial Cocktail= | |Radial Cocktail=2.5mg Verapamil, 200mcg NTG, 60u/kg Heparin, 1/2 heparin dose if on annticoagulation | ||
|Groin Setup=6fr sheath, JL4 / JR4 | |Groin Setup=6fr sheath, JL4 / JR4 | ||
|Closure Device=Perclose | |Closure Device=Perclose | ||
|Right Heart Setup=RN to put in brachial IV,IF IV fails scan and prep RIJ, 6/7 Slender, 7F TD Swan | |||
|Intervention Setup=Runthrough | |||
|Phone Number=1-415-730-5302 | |Phone Number=1-415-730-5302 | ||
}} | }} | ||
Line 14: | Line 16: | ||
===CTO=== | ===CTO=== | ||
*4 port manifold fully hooked up for second guide. | *4 port manifold fully hooked up for second guide. | ||
=== Bedside IABP Removal: === | |||
* .025 x 260 wire | |||
* .035 x 150 wire | |||
* 5FR MP diagnostic catheter | |||
* Perclose |
Revision as of 15:52, 3 May 2024
Glove size | 7.5 Latex (purple) |
---|---|
Access |
|
Radial Setup |
|
Radial Cocktail |
|
Groin Setup |
|
Closure Device |
|
Right Heart Setup |
|
Intervention Setup |
|
Phone Number | 1-415-730-5302 |
Pager Number |
Procedure preferences:
CTO
- 4 port manifold fully hooked up for second guide.
Bedside IABP Removal:
- .025 x 260 wire
- .035 x 150 wire
- 5FR MP diagnostic catheter