Aveir: Difference between revisions
No edit summary |
No edit summary |
||
Line 17: | Line 17: | ||
-4x pressure tubing (labeled A, B, C, D) | -4x pressure tubing (labeled A, B, C, D) | ||
-50-60cc syringe | -50-60cc syringe x2 | ||
- | -8fr pinnacle (or 8f dilator) | ||
-7cm floppy tip 180cm amplatz super stiff | -7cm floppy tip 180cm .035" amplatz super stiff | ||
- | -dilator 20f coons | ||
-0.0 PDS + needle driver | -0.0 PDS + needle driver | ||
-radpad | |||
-rampart cover | |||
-ioban | |||
-access cover | |||
Revision as of 22:27, 16 January 2024
RN:
-2x 1L bags NS with 2000u heparin per liter bag. One bag on gravity (these 2 lines will be labeled A/B), one on pressure (these 2 lines will be labeled C/D). 4x non pump tubings (2 per bag) labeled as listed above, spiked and primed. Optionally, if you want to clear the air from the gravity (A/B) lines faster, you can put it on pressure to flush, then immediately come off pressure after they're flushed, as they need to be on gravity during the case per protocol.
-double label each line - one on roller clamp and one on the end where you attach to the extension.
-MD will verbalize when to flush and when to set to 1 drop per second (via roller clamp.)
-1L heparinized saline (10,000u heparin) on the scrub table
-50cc omnipaque or visipaque if indicated (can be cut to ~50/50)
-lidocaine/bupivicaine
Tech:
-4x pressure tubing (labeled A, B, C, D)
-50-60cc syringe x2
-8fr pinnacle (or 8f dilator)
-7cm floppy tip 180cm .035" amplatz super stiff
-dilator 20f coons
-0.0 PDS + needle driver
-radpad
-rampart cover
-ioban
-access cover
created 03/29/23 zr