Paravalvular leak- Mitral: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
(12 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Warn|This procedures equipment is highly variable, consult with the physician before opening expensive stuff.}} | |||
All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1. | ==Notes== | ||
*Various equipment needed is dependent upon size of leak. | |||
*All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1. | |||
*Total Length of FlexCath: 81cm. | |||
*Total Length of Agilis: 71cm | |||
*If Flexcath is an acceptable option, use it. Much cheaper than agilis. | |||
*AVPII cable length: 100cm Cables can be daisy-chained! | |||
*90cm Shuttle Sheath is not long enough to put into FlexCath. Will have to remove flex cath.<br /> | |||
=== | ===Misc Supplies:=== | ||
==== Open ==== | ====Open==== | ||
* | *0-Ethibond | ||
* | *Micropuncture | ||
* | *Perclose | ||
*3-port manifold naked (no ACIST) - always open! | |||
*60cc syringe | |||
==== Standby ==== | ====Standby==== | ||
* | *Watchdog | ||
* | *stopcock | ||
* | *Mustang for septostomy | ||
*priority pack | |||
*180* torqvue (French size not important here, only using for the cable.) | |||
=== | ===Sheaths:=== | ||
==== Open ==== | ====Open==== | ||
* | *8F pinnacle | ||
* | *5F Pinnacle (for shuttle sheath not for access) | ||
* | *12F Dryseal | ||
* | *110cm Shuttle sheaths (Size depends on occluder) | ||
* | *Agilis small curve | ||
=== | ====Standby==== | ||
*4fr x 10cm Pinnacle - (A-line) | |||
*Cook 30cm | |||
===Wires:=== | |||
==== | ====Open==== | ||
* | *260 Standard J | ||
* | *Straight Glide 260cm | ||
* | *Angled Glide 260cm | ||
* | *Amplatz ES 260cm | ||
*.032 260J | |||
=== | ===Catheters:=== | ||
==== Open ==== | ====Open==== | ||
* | *5F MPA 100 cm with a 125cm on standby | ||
{{Note|The deployment cable for the ADO can be daisy-chained for more length!}} | |||
=== | ====Standby==== | ||
*5fr IM diagnostic | |||
*5fr JR4 diagnostic | |||
*Berenstein 125cm (Spies) | |||
===Transseptal=== | |||
{{Note|Not needed if recent transseptal procedure performed}} | |||
====Open==== | |||
=== | *Baylis machine | ||
*Baylis cable | |||
*Grounding pad | |||
*Large curve C1 Baylis needle | |||
*8.5fr SL1 transseptal sheath | |||
===Device embolization / retrieval:=== | |||
====Standby==== | |||
*EnSnare or Gooseneck | |||
*16 or 18fr x 33cm Dryseal | |||
*JR4 Guide | |||
* EnSnare or Gooseneck | |||
* 16 or 18fr x 33cm Dryseal | |||
[[Category:Procedures]] | [[Category:Procedures]] |
Latest revision as of 20:22, 9 December 2022
Warning: This procedures equipment is highly variable, consult with the physician before opening expensive stuff.
Notes
- Various equipment needed is dependent upon size of leak.
- All shuttle sheaths and plugs are located on the "plug cart" in the sterile core behind lab 1.
- Total Length of FlexCath: 81cm.
- Total Length of Agilis: 71cm
- If Flexcath is an acceptable option, use it. Much cheaper than agilis.
- AVPII cable length: 100cm Cables can be daisy-chained!
- 90cm Shuttle Sheath is not long enough to put into FlexCath. Will have to remove flex cath.
Misc Supplies:
Open
- 0-Ethibond
- Micropuncture
- Perclose
- 3-port manifold naked (no ACIST) - always open!
- 60cc syringe
Standby
- Watchdog
- stopcock
- Mustang for septostomy
- priority pack
- 180* torqvue (French size not important here, only using for the cable.)
Sheaths:
Open
- 8F pinnacle
- 5F Pinnacle (for shuttle sheath not for access)
- 12F Dryseal
- 110cm Shuttle sheaths (Size depends on occluder)
- Agilis small curve
Standby
- 4fr x 10cm Pinnacle - (A-line)
- Cook 30cm
Wires:
Open
- 260 Standard J
- Straight Glide 260cm
- Angled Glide 260cm
- Amplatz ES 260cm
- .032 260J
Catheters:
Open
- 5F MPA 100 cm with a 125cm on standby
Note: The deployment cable for the ADO can be daisy-chained for more length!
Standby
- 5fr IM diagnostic
- 5fr JR4 diagnostic
- Berenstein 125cm (Spies)
Transseptal
Note: Not needed if recent transseptal procedure performed
Open
- Baylis machine
- Baylis cable
- Grounding pad
- Large curve C1 Baylis needle
- 8.5fr SL1 transseptal sheath
Device embolization / retrieval:
Standby
- EnSnare or Gooseneck
- 16 or 18fr x 33cm Dryseal
- JR4 Guide