*Micropuncture (for woggle only)
*Micropuncture (for woggle only)


 
===Standby: ===
Standby:  


*8.5F TourGuide
*8.5F TourGuide
*6F balloon wedge
*6F balloon wedge
*5F balloon tip pacer  
*5F balloon tip pacer  
<br />


==Procedure==
==Procedure==


*Single Venous access
#Single Venous access
*Double Preclose
#Double Preclose
*8F Sheath inserted
#8F Sheath inserted
*Pigtail and J wire advanced to RV
#Pigtail and J wire advanced to RV
*J wire exchanged for Safari
#J wire exchanged for Safari
**Shave back of Safari for pacing
#*Shave back of Safari for pacing
* Sheath exchanged for E Sheath
#Sheath exchanged for E Sheath
*Valve delivery system advanced
#Valve delivery system advanced
*Pacer tested
#Pacer tested
*Valve deployed
#Valve deployed
*Safari exchanged for J wire
#Safari exchanged for J wire
*Perclose completed and woggle placed.
#Perclose completed and woggle placed.
*Voila.
#Voila.


<br />
<br />

Revision as of 22:25, 8 December 2021

Anesthesia Imaging Access ACIST Manifold
MAC Fluoro, TTE

Femoral Vein

No No

Supplies

  • Standard TAVR backtable setup
  • 8F Sheath
  • 150 J
  • 260J
  • Safari
  • Alligator Clip Pacing cable
  • 6F Angled Pigtail
  • 0 Prolene
  • Micropuncture (for woggle only)

Standby:

  • 8.5F TourGuide
  • 6F balloon wedge
  • 5F balloon tip pacer

Procedure

  1. Single Venous access
  2. Double Preclose
  3. 8F Sheath inserted
  4. Pigtail and J wire advanced to RV
  5. J wire exchanged for Safari
    • Shave back of Safari for pacing
  6. Sheath exchanged for E Sheath
  7. Valve delivery system advanced
  8. Pacer tested
  9. Valve deployed
  10. Safari exchanged for J wire
  11. Perclose completed and woggle placed.
  12. Voila.