Tricuspid ViV: Difference between revisions
From Bay Area Structural Heart Wiki
No edit summary |
No edit summary |
||
Line 28: | Line 28: | ||
*Micropuncture (for woggle only) | *Micropuncture (for woggle only) | ||
===Standby: === | |||
Standby: | |||
*8.5F TourGuide | *8.5F TourGuide | ||
*6F balloon wedge | *6F balloon wedge | ||
*5F balloon tip pacer | *5F balloon tip pacer | ||
==Procedure== | ==Procedure== | ||
#Single Venous access | |||
#Double Preclose | |||
#8F Sheath inserted | |||
#Pigtail and J wire advanced to RV | |||
#J wire exchanged for Safari | |||
#*Shave back of Safari for pacing | |||
#Sheath exchanged for E Sheath | |||
#Valve delivery system advanced | |||
#Pacer tested | |||
#Valve deployed | |||
#Safari exchanged for J wire | |||
#Perclose completed and woggle placed. | |||
#Voila. | |||
<br /> | <br /> |
Revision as of 22:25, 8 December 2021
Anesthesia | Imaging | Access | ACIST | Manifold |
---|---|---|---|---|
MAC | Fluoro, TTE |
Femoral Vein |
No | No |
Supplies
- Standard TAVR backtable setup
- 8F Sheath
- 150 J
- 260J
- Safari
- Alligator Clip Pacing cable
- 6F Angled Pigtail
- 0 Prolene
- Micropuncture (for woggle only)
Standby:
- 8.5F TourGuide
- 6F balloon wedge
- 5F balloon tip pacer
Procedure
- Single Venous access
- Double Preclose
- 8F Sheath inserted
- Pigtail and J wire advanced to RV
- J wire exchanged for Safari
- Shave back of Safari for pacing
- Sheath exchanged for E Sheath
- Valve delivery system advanced
- Pacer tested
- Valve deployed
- Safari exchanged for J wire
- Perclose completed and woggle placed.
- Voila.