Tricuspid ViR: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
No edit summary
Line 23: Line 23:


==Supplies==
==Supplies==
 
===Open:===
*Standard TAVR backtable setup with Certitude delivery system
*Standard TAVR backtable setup with Certitude delivery system
*8F Sheath
*8F Sheath
Line 35: Line 35:
*Perclose x 1
*Perclose x 1


 
===Standby: ===
Standby:  
 
*Sizing Balloon?
*Sizing Balloon?
*5F MPA
*5F MPA
Line 46: Line 44:




'''PVL Closure:'''
==PVL Closure:==
 
* Plug Cart in room.  May be ASO, Cardioform, or AVP2
* Plug Cart in room.  May be ASO, Cardioform, or AVP2
* Standard Glidewire for crossing
* Standard Glidewire for crossing
* Amplatz ES if using Trevisio/Torqvue
* Amplatz ES if using Trevisio/Torqvue
<br />


==Procedure==
==Procedure==
 
#IJ accessS
*IJ accessS
#Single preclose
*Single preclose
#Certitude Sheath Advanced
*Certitude Sheath Advanced
#Pigtail and J wire advanced to RV
*Pigtail and J wire advanced to RV
#J wire exchanged for Safari
*J wire exchanged for Safari
#*Shave back of Safari for pacing
**Shave back of Safari for pacing
#Valve delivery system advanced
*Valve delivery system advanced
#Pacer tested
*Pacer tested
#Valve deployed
*Valve deployed
#Safari exchanged for J wire
*Safari exchanged for J wire
#Perclose completed and woggle placed.
*Perclose completed and woggle placed.
#Voila.
*Voila.


<br />
<br />

Revision as of 22:19, 8 December 2021

THIS PAGE IS BASED OFF THE 1 PREVIOUS TVIR. VERY PRELIMINARY.


Due to the open nature of the tricuspid surgical ring, PVL is highly likely post transcatheter valve placement.


Anesthesia Imaging Access ACIST Manifold
GA Fluoro, TEE

LEFT IJ Vein

No No

Supplies

Open:

  • Standard TAVR backtable setup with Certitude delivery system
  • 8F Sheath
  • 150 J
  • 260J
  • Safari
  • Alligator Clip Pacing cable
  • 6F Angled Pigtail
  • 0 Prolene
  • Micropuncture
  • Perclose x 1

Standby:

  • Sizing Balloon?
  • 5F MPA
  • 8.5F TourGuide
  • Agilis
  • 6F balloon wedge
  • Pacing Supplies


PVL Closure:

  • Plug Cart in room. May be ASO, Cardioform, or AVP2
  • Standard Glidewire for crossing
  • Amplatz ES if using Trevisio/Torqvue

Procedure

  1. IJ accessS
  2. Single preclose
  3. Certitude Sheath Advanced
  4. Pigtail and J wire advanced to RV
  5. J wire exchanged for Safari
    • Shave back of Safari for pacing
  6. Valve delivery system advanced
  7. Pacer tested
  8. Valve deployed
  9. Safari exchanged for J wire
  10. Perclose completed and woggle placed.
  11. Voila.