ASD Closure: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
Line 64: Line 64:
#Possible sizing balloon used here
#Possible sizing balloon used here
#Prep and deliver device
#Prep and deliver device
===Pericardiocentesis===
{{Pericardiocentesis}}


===Emergency Device embolization/retrieval Supplies:===
===Emergency Device embolization/retrieval Supplies:===
Line 128: Line 124:
* ASD closed
* ASD closed
* Insertion sites closed
* Insertion sites closed
<br />
===Pericardiocentesis===
{{Pericardiocentesis}}<br />
===Emergency Device embolization/retrieval Supplies:===
*16 or 18 Fr x 33 cm Dry Seal Sheath
*6 or 7 Fr Ensnare Kit or Gooseneck Snare


<HR />
<HR />
Line 200: Line 187:
*Device = SEPTAL OCCLUDERS (All available sizes)
*Device = SEPTAL OCCLUDERS (All available sizes)


===Emergency Supplies:===
*Pericardiocentesis Tray
*Pericardiocentesis Supplies:
**5Fr VS Micropuncture
**Dilators
**0.035 J Wire 150 cm
**60 ml syringe
**Pericardiocentesis drainage bag
===Emergency Device embolization/retrieval Supplies:===
*16 or 18 Fr x 33 cm Dry Seal Sheath
*6 or 7 Fr Ensnare Kit or Gooseneck Snare


[[Category:Procedures]]
[[Category:Procedures]]
<HR />
<HR />
APPROVED: MD initials MM/YY
APPROVED: MD initials MM/YY

Revision as of 14:29, 2 September 2021

DR. Daniels - DRAFT

RFV access, GENERAL ANESTHESIA with TEE

Medications:

  • Pre-Op Antibiotics : Ancef IV
  • Antiplatelet : Aspirin & Plavix

Sheaths:

Open

  • 5Fr Micropuncture Kit
  • 8fr Pinnacle

Standby

  • 4 Fr x 10 cm Pinnacle (possible femoral arterial line for anesthesia

Wires:

Open

  • 0.035 x 260 Rosen
  • J Wire 0.035 x 260

Standby

  • 0.035 x 250 Amplatz Super Stiff 1cm tip
  • BMW 190cm
  • Wholey 145cm
  • Cordis “J” 0.032 x 260 cm

Catheters:

Open

  • 5Fr MPA 100 cm diagnostic

Misc. Supplies:

  • 3-port manifold
  • Large Sterile Bowl with 1L Heparinized Saline for Device Prep USE ONLY
  • 1 bowl with 20% contrast/80% saline for Sizing Balloon prep
  • 60 ml syringe
  • 20 ml syringe

Devices on standby:

  • Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS
  • Perclose
  • Sizing Balloon (Range: 18, 24, 34mm)
  • TorqVue Delivery Sheath (Range: 7, 8, 9, 10, 12Fr)
  • Device = SEPTAL OCCLUDERS (All available sizes)
  • Cardioform devices - If needing to deliver cardioform sheath, use a 7F shuttle sheath dilator.

Procedure

  1. Access with micropuncture and ultrasound
  2. 8fr sheath (might pre-close)
  3. MP with Rosen to cross ASD
  4. Exchange Rosen for 260J to LUPV
  5. Possible sizing balloon used here
  6. Prep and deliver device

Emergency Device embolization/retrieval Supplies:

  • 16 or 18 Fr x 33 cm Dry Seal Sheath
  • 6 or 7 Fr Ensnare Kit or Gooseneck Snare

DR. Spies - DRAFT

RFV access. (x2 if using ICE)

Medications:

  • Pre-Op Antibiotics : Ancef IV
  • Antiplatelet : Aspirin & Plavix

Open

  • 5Fr Micropuncture  Kit  
  • 8fr Pinnacle (for preclose dilation)
  • .035 Amplatz Extra Stiff
  • .035 Exchange J
  • 5Fr MPA 100 cm diagnostic
  • 0-Prolene for woggle or tie at end

Standby

  • 8F TorqVue
  • 24 Sizing balloon
  • 6F Balloon Wedge
  • Stopcock
  • 3-port manifold

Misc

  • Large Sterile Bowl with 1L Heparinized Saline for Device Prep USE ONLY
  • 10% Contrast mix for sizing balloon
  • 60 ml syringe
        • 9F 25cm Brite Tip if using ICE
        • SwiftLink (ICE)
        • 8F Accunav (ICE)

Devices on standby:

Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS

  • Sizing Balloon (Range: 18, 24, 34mm)
  • TorqVue Delivery Sheath (Range: 7, 8, 9, 10, 12Fr)
  • Device = SEPTAL OCCLUDERS (All available sizes)

Procedure:

  • Access with US and Micropuncture
  • 8F Sheath inserted possible RHC performed with 6F Balloon Wedge
  • (If Using) ICE catheter inserted, bubble study performed
  • MPA and J wire advanced across septum
  • J wire exchanged for Amplatz ES
  • Sizing balloon inserted
  • Measurements taken on x-ray image
  • ASD closed
  • Insertion sites closed

APPROVED: MD initials MM/YY



DR. Hui - DRAFT

RFV access, GENERAL ANESTHESIA with TEE

Medications:

  • Pre-Op Antibiotics : Ancef IV
  • Antiplatelet : Aspirin & Plavix

Sheaths:

Open

  • 5Fr Micropuncture  Kit  
  • 6fr pinnacle for RFV access

Standby

  • 4 Fr x 10 cm Pinnacle (possible femoral arterial line for anesthesia

Wires:

Open

  • 0.035 x 250 Amplatz Straight Tip Super Stiff
  • Cordis “J” Wire 0.035 x 150cm

Standby

  • BMW 190cm
  • Versacore 145cm
  • Cordis “J” 0.035 x 260 cm
  • Amplatzer Guide 0.035 x 260 cm

Catheters:

Open

  • 6Fr MPA 100 cm diagnostic

Misc. Supplies:

  • 3-port manifold with a stopcock on the front
  • Large Sterile Bowl with 1L Heparinized Saline for Device Prep USE ONLY
  • (3)packs of sterile towels
  • 1 bowl with 20% contrast/80% saline for Sizing Balloon prep
  • 60 ml syringe
  • (2) 20 ml syringe

Devices on standby:

Amplatzer Supplies & Occluder Devices: OPEN WHEN MD REQUESTS

  • Sizing Balloon (Range: 18, 24, 34mm)
  • TorqVue Delivery Sheath (Range: 7, 8, 9, 10, 12Fr)
  • Device = SEPTAL OCCLUDERS (All available sizes)

APPROVED: MD initials MM/YY