Valve in MAC with Antegrade Lampoon: Difference between revisions

From Bay Area Structural Heart Wiki
(updating from case log pt DP)
Line 1: Line 1:
General Anesthesia, TEE
'''GENERAL ANESTHESIA AND TEE IMAGING, RADIAL ART LINE BY ANESTHESIA'''
 
'''BIPLANE IMAGING'''
 
'''OVERLAY FOR SENTINEL'''
 
'''PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN'''




Line 6: Line 12:
https://www.jtcvs.org/article/S0022-5223(18)31545-9/pdf
https://www.jtcvs.org/article/S0022-5223(18)31545-9/pdf


Per Rosalie:
TAVR/TMVI
#Edwards Sapien 3 Ultra (20, 23 & 26mm) and Sapien 3 (29mm) – scan the valve barcode (box) in McKesson for documentation and charges.  Bundle includes valve, delivery system, crimper, e sheath intro set, balloon cath & locking syringe.  With the new inventory system (POU) space is limited in entering item full description.   If pre dilatation Edwards balloon is necessary free text the balloon used in procedure notes (McKesson).
#Medtronic Core Valve – all items are charge separately.  Scan all barcodes (delivery system, loading system and valve).
MITRAL CLIP (Mitral/Tricuspid):
#Use the barcode on Mckesson screen in Lab 1 – Mitraclip (Abbott) bundle consists of (1) Steerable Guide Catheter, (2) NTR Clip Delivery System & (1) XTR Clip Delivery System.
'''GENERAL ANESTHESIA AND TEE IMAGING, RADIAL ART LINE BY ANESTHESIA'''
'''ACCESS 2 FEMORAL VEINS (TAVR AND PACER)'''
'''PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN'''
===Access sites:===
===Access sites:===
24F RFV
26F RFV


8F LFV
8F LFV
Line 15: Line 39:


===Open:===
===Open:===
Standard Basilica Equipment
Sentinel
 
.014 Astato xs 20 guidewire 180cm
 
Piggyback wire converter 4fr x 145
 
26F Dryseal
 
14mm Armada Balloon
 
Bovie pen
 
Grounding Pad
 
(2) Watchdog devices
 
(2) Stopcocks
 
4 hemostats
 
(3) 60ml syringes
 
(2) 12 inch extension tubing
 
Bowl of D5
 
SL1
 
Baylis Needle
 
8F 35cm Brite Tip Sheath
 
Josephson Pacing Wire
 
Remington Cable
 
Blue Pacing Cable


Standard Transeptal Equipment
(2) .032 260cm J wire


Standard TMVR Equipment
(1) .035 260cm J wire


??Sentinel Equipment**
(1) .035 150cm J wire


Safari
300cm Grandslam


24F Dryseal
Safari
 
Amplatz SS 1cm
 
26F Dryseal


(2) Agilis sm curl
(2) Agilis sm curl
Line 32: Line 96:


14mm Armada Balloon
14mm Armada Balloon
Priority Pack


Balloon Pump
Balloon Pump


6F JR4 Guide/ 6F MP
8F Sheath
 
6F JR4 Guide


6F JL3.5 Guide
6F JL3.5 Guide


7F JR4 Guide
7F JR4 Guide
5F MPA1
6F Straight Pigtail
5/6 Slender Sheath


18/30 Ensnare
18/30 Ensnare
Line 57: Line 131:
6F MP Guide
6F MP Guide


7F Langston
8F 90cm Shuttle sheath and 125cm Pigtail for measuring gradient post valve placement<br />
<br />


===Rough Procedural Plan:===
===Rough Procedural Plan:===
Line 64: Line 137:


Preclose RFV x 2
Preclose RFV x 2
Preclose LFA


SL1- transeptal puncture
SL1- transeptal puncture

Revision as of 01:21, 11 December 2020

GENERAL ANESTHESIA AND TEE IMAGING, RADIAL ART LINE BY ANESTHESIA

BIPLANE IMAGING

OVERLAY FOR SENTINEL

PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN


MAC- Mitral Annular Calcification

https://www.jtcvs.org/article/S0022-5223(18)31545-9/pdf


Per Rosalie:

TAVR/TMVI

  1. Edwards Sapien 3 Ultra (20, 23 & 26mm) and Sapien 3 (29mm) – scan the valve barcode (box) in McKesson for documentation and charges.  Bundle includes valve, delivery system, crimper, e sheath intro set, balloon cath & locking syringe.  With the new inventory system (POU) space is limited in entering item full description.   If pre dilatation Edwards balloon is necessary free text the balloon used in procedure notes (McKesson).
  2. Medtronic Core Valve – all items are charge separately.  Scan all barcodes (delivery system, loading system and valve).

MITRAL CLIP (Mitral/Tricuspid):

  1. Use the barcode on Mckesson screen in Lab 1 – Mitraclip (Abbott) bundle consists of (1) Steerable Guide Catheter, (2) NTR Clip Delivery System & (1) XTR Clip Delivery System.


GENERAL ANESTHESIA AND TEE IMAGING, RADIAL ART LINE BY ANESTHESIA

ACCESS 2 FEMORAL VEINS (TAVR AND PACER)

PRE PROCEDURE: TYPE AND CROSS, ASPIRIN GIVEN

Access sites:

26F RFV

8F LFV

8F LFA

Open:

Sentinel

.014 Astato xs 20 guidewire 180cm

Piggyback wire converter 4fr x 145

26F Dryseal

14mm Armada Balloon

Bovie pen

Grounding Pad

(2) Watchdog devices

(2) Stopcocks

4 hemostats

(3) 60ml syringes

(2) 12 inch extension tubing

Bowl of D5

SL1

Baylis Needle

8F 35cm Brite Tip Sheath

Josephson Pacing Wire

Remington Cable

Blue Pacing Cable

(2) .032 260cm J wire

(1) .035 260cm J wire

(1) .035 150cm J wire

300cm Grandslam

Safari

Amplatz SS 1cm

26F Dryseal

(2) Agilis sm curl

300 cm Runthrough wire

14mm Armada Balloon

Priority Pack

Balloon Pump

8F Sheath

6F JR4 Guide

6F JL3.5 Guide

7F JR4 Guide

5F MPA1

6F Straight Pigtail

5/6 Slender Sheath

18/30 Ensnare

25mm Gooseneck snare

Preclose x 2

0 Ethibond

0 Prolene

Standby:

12F Flexcath

6F MP Guide

8F 90cm Shuttle sheath and 125cm Pigtail for measuring gradient post valve placement

Rough Procedural Plan:

Obtain access as listed above.

Preclose RFV x 2

Preclose LFA

SL1- transeptal puncture

SL1 exchanged for 24F Dryseal

Agilis x 2 inserted

7F JR4 with ensnare to LFA

6F JR4 through one of the agilis.

Runthrough in 6F JR4 and snared through 7F in LV

6F JR4 removed and reinserted over .032 wire---- or 6FMP??

Lampoon equipment advanced through 6F JR4/MP

6FJL3.5 advanced over Runthrough

25mm snare through JL3.5

Anterior leaflet traversed.-- Test bovie at 30 cut. Increase to 70 cut for traversal and laceration.

After leaflet traversal and system snared- 7F guide and Runthrough removed.

Balloon pump inserted.

Pacer inserted.

Leaflet lacerated.

Lampoon system deconstructed.

Pigtail advanced with Safari

Pigtail out.

Septostomy

Valve inserted and deployed.

Pigtail for wire removal



*ECMO??

*Possible ASD Closure