TAVI-JenaValve: Difference between revisions

From Bay Area Structural Heart Wiki
No edit summary
Line 3: Line 3:
==Daniels/Spies - Draft==
==Daniels/Spies - Draft==
ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX
ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX
If patient has permanent pacer, no need for TVP. Pacing is only used for backup (not deployment).


===Sheaths:===
===Sheaths:===

Revision as of 01:00, 8 July 2020


Daniels/Spies - Draft

ACIST A1000V SYRINGE USED WITH 50/50 CONTRAST MIX

If patient has permanent pacer, no need for TVP. Pacing is only used for backup (not deployment).

Sheaths:

  • 5Fr Micropunture Kit
  • 6Fr x 10cm sheath
  • 8Fr x 10 cm sheath (Dilator used only)
  • 8Fr x 35 cm Brite Tip Sheath
  • 9Fr x 10cm sheath
  • 18F Cook Sheath

Wires:

  • (2) Cordis 150J
  • Cordis 260J
  • Safari 2

Catheters:

  • 5Fr MPA
  • 5Fr MPB
  • 5Fr Angled Pigtail

Medications on table:

  • Lido/Bupivicaine 50/50
  • Epinephrine 10mcg/ml in red medallion syringe (From anesthesia)

Miscellaneous Supplies

  • 3-port manifold kit
  • Acist hand control
  • 2L cold saline
  • 2L room temp saline
  • (2) 60ml syringes
  • (2) 20ml syringes
  • stopcock
  • co-pilot
  • 108cm tubing
  • 500ml hep saline on pressure bag
  • back table cover
  • (3) Perclose
  • (5) bowls

Transvenous pacemaker supplies

  • 5Fr Josephson Pacing catheter
  • Dual Red/Black Pacing Remington cables
  • EP Quad Cable

PROCEDURAL INFO:

After initial injection lock table and outline AO on boom